1.1.04-2249 | 6.14.2018 |
AM211 |
2.0.00-2317 | 6.23.2021 |
Resolves bug that prevented log modes from working correctly when monitor was set to 6500K 2.4 gamma.
Late model AM211 with serial numbers containing the letter P (e.g. MA211P0031 or later) use AM211P firmware below.
AM211P |
2.0.00-2326 | 1.6.2022 |
Resolves possible ethernet connection bug on some units.
Late model AM211 with serial numbers containing the letter P (e.g. MA211P0031 or later) use AM211P firmware. AM211 without P in the Serial number use AM211 firmware above.
AM250 |
1.1.04-2249 | 6.14.2018 |
AM420 |
1.1.04-2249 | 6.14.2018 |
AM550 |
1.1.04-2249 | 6.14.2018 |
BM090 |
1.1.04-2249 | 06.14.2018 |
BM210 |
1.1.04-2249 | 06.14.2018 |
Adds Sundance Marker.
BM211 |
2.0.00-2326 | 1.6.2022 |
BM230 |
1.1.04-2249 | 06.14.2018 |
Adds Sundance Marker.
BM240 |
1.1.04-2249 | 06.14.2018 |
BM241 |
2.0.00-2326 | 1.6.2022 |
BM420 |
2.0.00-2326 | 1.6.2022 |
BM550 |
2.0.00-2326 | 1.6.2022 |
CM171 |
1.1.04-2249 | 06.14.2018 |
Adds Sundance Marker.
CM172 |
1.1.04-2249 | 06.14.2018 |
Adds Sundance Marker.
In order to update from firmware version 0.9.XX to firmware 1.0.00-1958 or later you must first send your OLED monitor to Flanders Scientific for a factory level update. This requirement only applies to OLED units, if you also own LCD based units those can be updated in the field without first sending your monitor back to FSI. We apologize for any inconvenience this may cause, but this process is necessary in order to support these powerful new features. As always these updates are optional and there is no requirement to update if you do not need the new capabilities offered by the firmware updates. Contact Support@FlandersScientific.com for more details.
Download Firmware
CM240 |
1.1.04-2249 | 06.14.2018 |
Adds Sundance Marker.
CM250 |
1.1.04-2249 | 06.14.2018 |
Adds Sundance Marker.
In order to update from firmware version 0.9.XX to firmware 1.0.00-1958 or later you must first send your OLED monitor to Flanders Scientific for a factory level update. This requirement only applies to OLED units, if you also own LCD based units those can be updated in the field without first sending your monitor back to FSI. We apologize for any inconvenience this may cause, but this process is necessary in order to support these powerful new features. As always these updates are optional and there is no requirement to update if you do not need the new capabilities offered by the firmware updates. Contact Support@FlandersScientific.com for more details.
Download Firmware
CM320TD |
1.1.04-2249 | 06.14.2018 |
Adds Sundance Marker.
Download CFE
If you are upgrading a monitor with a version older than 1937, you will also need to update the monitor's CFE. Perform the Firmware Update before CFE Update. Copy all unzipped files to monitor and select Update CFE in Color Management.
CM420TD |
1.1.04-2249 | 06.14.2018 |
CM500TD |
1.1.04-2249 | 06.14.2018 |
Adds Sundance Marker.
Download CFE
If you are upgrading a monitor with a version older than 1937, you will also need to update the monitor's CFE. Perform the Firmware Update before CFE Update. Copy all unzipped files to monitor and select Update CFE in Color Management.
DM160 |
2.0.00-2379 | 11.29.2024 |
Update to Fast Mode operation when no signal is present: with fast mode function turned on, if no signal is present, the monitor will now automatically disable fast mode to provide you with access to menus. Provided the Fast Mode function remains activated Fast mode will automatically reenable when a signal is present again. This update also fixes a bug from the previous build where booting the monitor with no signal present while fast mode was still active from last session would cause a no menu/no image condition even when the signal was reconnected.
DM170 |
2.0.00-2379 | 11.29.2024 |
Update to Fast Mode operation when no signal is present: with fast mode function turned on, if no signal is present, the monitor will now automatically disable fast mode to provide you with access to menus. Provided the Fast Mode function remains activated Fast mode will automatically reenable when a signal is present again. This update also fixes a bug from the previous build where booting the monitor with no signal present while fast mode was still active from last session would cause a no menu/no image condition even when the signal was reconnected.
If updating from 2.0.00-2282 or later do not update if Reset Factory Alignment menu item is greyed out. If greyed out, run AutoCal before updating or contact Support@FlandersScientific.com for more information.
Download Latest Firmware
Updating to the AutoCal compatible firmware above will not delete previous calibrations. However, once you update to AutoCal compatible firmware please note that any new third party calibration LUTs will need to be saved only to the user1, user2, and user3 memory positions. See the latest calibration guides for details.
For users on a firmware build currently older than 1.0.04-2254 that would like to update to the last Pre-AutoCal firmware build, 1.1.04-2254 is provided below for download:
Download Firmware 1.1.04-2254
DM211 |
2.0.00-2379 | 11.29.2024 |
Update to Fast Mode operation when no signal is present: with fast mode function turned on, if no signal is present, the monitor will now automatically disable fast mode to provide you with access to menus. Provided the Fast Mode function remains activated Fast mode will automatically reenable when a signal is present again. This update also fixes a bug from the previous build where booting the monitor with no signal present while fast mode was still active from last session would cause a no menu/no image condition even when the signal was reconnected.
DM220 |
2.0.00-2379 | 11.29.2024 |
Update to Fast Mode operation when no signal is present: with fast mode function turned on, if no signal is present, the monitor will now automatically disable fast mode to provide you with access to menus. Provided the Fast Mode function remains activated Fast mode will automatically reenable when a signal is present again. This update also fixes a bug from the previous build where booting the monitor with no signal present while fast mode was still active from last session would cause a no menu/no image condition even when the signal was reconnected.
DM231 |
2.0.00-2379 | 11.29.2024 |
Update to Fast Mode operation when no signal is present: with fast mode function turned on, if no signal is present, the monitor will now automatically disable fast mode to provide you with access to menus. Provided the Fast Mode function remains activated Fast mode will automatically reenable when a signal is present again. This update also fixes a bug from the previous build where booting the monitor with no signal present while fast mode was still active from last session would cause a no menu/no image condition even when the signal was reconnected.
DM240 |
2.0.00-2379 | 11.29.2024 |
Update to Fast Mode operation when no signal is present: with fast mode function turned on, if no signal is present, the monitor will now automatically disable fast mode to provide you with access to menus. Provided the Fast Mode function remains activated Fast mode will automatically reenable when a signal is present again. This update also fixes a bug from the previous build where booting the monitor with no signal present while fast mode was still active from last session would cause a no menu/no image condition even when the signal was reconnected.
If updating from 2.0.00-2282 or later do not update if Reset Factory Alignment menu item is greyed out. If greyed out, run AutoCal before updating or contact Support@FlandersScientific.com for more information.
Download Latest Firmware
Updating to the AutoCal compatible firmware above will not delete previous calibrations. However, once you update to AutoCal compatible firmware please note that any new third party calibration LUTs will need to be saved only to the user1, user2, and user3 memory positions. See the latest calibration guides for details.
For users on a firmware build currently older than 1.0.04-2254 that would like to update to the last Pre-AutoCal firmware build, 1.1.04-2254 is provided below for download:
Download Firmware 1.1.04-2254
DM241 |
2.0.00-2379 | 11.29.2024 |
Update to Fast Mode operation when no signal is present: with fast mode function turned on, if no signal is present, the monitor will now automatically disable fast mode to provide you with access to menus. Provided the Fast Mode function remains activated Fast mode will automatically reenable when a signal is present again. This update also fixes a bug from the previous build where booting the monitor with no signal present while fast mode was still active from last session would cause a no menu/no image condition even when the signal was reconnected.
DM242 |
2.0.00-2379 | 11.29.2024 |
Update to Fast Mode operation when no signal is present: with fast mode function turned on, if no signal is present, the monitor will now automatically disable fast mode to provide you with access to menus. Provided the Fast Mode function remains activated Fast mode will automatically reenable when a signal is present again. This update also fixes a bug from the previous build where booting the monitor with no signal present while fast mode was still active from last session would cause a no menu/no image condition even when the signal was reconnected.
DM250 |
2.0.00-2379 | 11.29.2024 |
Update to Fast Mode operation when no signal is present: with fast mode function turned on, if no signal is present, the monitor will now automatically disable fast mode to provide you with access to menus. Provided the Fast Mode function remains activated Fast mode will automatically reenable when a signal is present again. This update also fixes a bug from the previous build where booting the monitor with no signal present while fast mode was still active from last session would cause a no menu/no image condition even when the signal was reconnected.
If updating from 2.0.00-2282 or later do not update if Reset Factory Alignment menu item is greyed out. If greyed out, run AutoCal before updating or contact Support@FlandersScientific.com for more information.
Download Latest Firmware
Updating to the AutoCal compatible firmware above will not delete previous calibrations. However, once you update to AutoCal compatible firmware please note that any new third party calibration LUTs will need to be saved only to the user1, user2, and user3 memory positions. See the latest calibration guides for details.
For users on a firmware build currently older than 1.0.04-2254 that would like to update to the last Pre-AutoCal firmware build, 1.1.04-2254 is provided below for download:
Download Firmware 1.1.04-2254
DM420 |
2.0.00-2379 | 11.29.2024 |
Update to Fast Mode operation when no signal is present: with fast mode function turned on, if no signal is present, the monitor will now automatically disable fast mode to provide you with access to menus. Provided the Fast Mode function remains activated Fast mode will automatically reenable when a signal is present again. This update also fixes a bug from the previous build where booting the monitor with no signal present while fast mode was still active from last session would cause a no menu/no image condition even when the signal was reconnected.
DM550 |
2.0.00-2379 | 11.29.2024 |
Update to Fast Mode operation when no signal is present: with fast mode function turned on, if no signal is present, the monitor will now automatically disable fast mode to provide you with access to menus. Provided the Fast Mode function remains activated Fast mode will automatically reenable when a signal is present again. This update also fixes a bug from the previous build where booting the monitor with no signal present while fast mode was still active from last session would cause a no menu/no image condition even when the signal was reconnected.
XM310K |
2.1.25 | 10.4.2022 |
Updates to 1.5G and 3G signal support. When Video Menu-> SDI Format -> AUTO is selected payload ID of the signal will be detected and followed. If Payload ID is missing from the output device the monitor will process the incoming signal as 4:2:2 YCbCr when set to AUTO, but this update allows the SDI Format Selection override (Video Menu-> SDI Format -> manual selection) to also work on 1.5G and 3G signals, not just 6G and 12G signals.
Requires new AWB calibration after update if updating from firmware older than 2.0.01.
Please verify again you are downloading firmware for an XM310K.
I Understand
XM311K |
2.1.25 | 10.4.2022 |
Updates to 1.5G and 3G signal support. When Video Menu-> SDI Format -> AUTO is selected payload ID of the signal will be detected and followed. If Payload ID is missing from the output device the monitor will process the incoming signal as 4:2:2 YCbCr when set to AUTO, but this update allows the SDI Format Selection override (Video Menu-> SDI Format -> manual selection) to also work on 1.5G and 3G signals, not just 6G and 12G signals.
Updates will not delete calibration LUTs, but please take note of currently used settings on your monitor as these may be reset during a firmware update.
Please verify again you are downloading firmware for an XM311K.
I Understand
XM551U |
2.1.25 | 10.4.2022 |
Updates to 1.5G and 3G signal support. When Video Menu-> SDI Format -> AUTO is selected payload ID of the signal will be detected and followed. If Payload ID is missing from the output device the monitor will process the incoming signal as 4:2:2 YCbCr when set to AUTO, but this update allows the SDI Format Selection override (Video Menu-> SDI Format -> manual selection) to also work on 1.5G and 3G signals, not just 6G and 12G signals.
Updates will not delete calibration LUTs, but please take note of currently used settings on your monitor as these may be reset during a firmware update.
Please verify again you are downloading firmware for an XM551U.
I Understand
XM552U |
2.1.25 | 10.4.2022 |
Updates to 1.5G and 3G signal support. When Video Menu-> SDI Format -> AUTO is selected payload ID of the signal will be detected and followed. If Payload ID is missing from the output device the monitor will process the incoming signal as 4:2:2 YCbCr when set to AUTO, but this update allows the SDI Format Selection override (Video Menu-> SDI Format -> manual selection) to also work on 1.5G and 3G signals, not just 6G and 12G signals.
Updates will not delete calibration LUTs, but please take note of currently used settings on your monitor as these may be reset during a firmware update.
Please verify again you are downloading firmware for an XM552U.
I Understand
XM650U |
2.1.25 | 10.4.2022 |
Updates to 1.5G and 3G signal support. When Video Menu-> SDI Format -> AUTO is selected payload ID of the signal will be detected and followed. If Payload ID is missing from the output device the monitor will process the incoming signal as 4:2:2 YCbCr when set to AUTO, but this update allows the SDI Format Selection override (Video Menu-> SDI Format -> manual selection) to also work on 1.5G and 3G signals, not just 6G and 12G signals.
Updates will not delete calibration LUTs, but please take note of currently used settings on your monitor as these may be reset during a firmware update.
If running firmware version 1.24 or earlier, this firmware update requires AWB to be performed on XM650U monitors. Please contact FSI Support for additional details before updating.
Please verify again you are downloading firmware for an XM650U.
I Understand
XM651U |
2.1.25 | 10.4.2022 |
Updates to 1.5G and 3G signal support. When Video Menu-> SDI Format -> AUTO is selected payload ID of the signal will be detected and followed. If Payload ID is missing from the output device the monitor will process the incoming signal as 4:2:2 YCbCr when set to AUTO, but this update allows the SDI Format Selection override (Video Menu-> SDI Format -> manual selection) to also work on 1.5G and 3G signals, not just 6G and 12G signals.
Updates will not delete calibration LUTs, but please take note of currently used settings on your monitor as these may be reset during a firmware update.
Please verify again you are downloading firmware for an XM651U.
I Understand
XM652U |
2.1.25 | 10.4.2022 |
Updates to 1.5G and 3G signal support. When Video Menu-> SDI Format -> AUTO is selected payload ID of the signal will be detected and followed. If Payload ID is missing from the output device the monitor will process the incoming signal as 4:2:2 YCbCr when set to AUTO, but this update allows the SDI Format Selection override (Video Menu-> SDI Format -> manual selection) to also work on 1.5G and 3G signals, not just 6G and 12G signals.
Updates will not delete calibration LUTs, but please take note of currently used settings on your monitor as these may be reset during a firmware update.
Please verify again you are downloading firmware for an XM652U.
I Understand
XMP310 |
2.4.68 | 11.13.2024 |
Big improvements to interlaced video monitoring capabilities for all XMP models providing high quality, reference grade monitoring of interlaced video signals. There are now 3 deinterlace toggles to choose from:
Interfield: fields are combined and shown as progressive.
Intrafield: fields are shown as interlaced on screen with proper temporal field order. This is the mode suggested for QC monitoring of interlaced sources as it will allow you to spot issues like field reversals.
Psf: for use with progressive segmented frame (PsF) signals. PsF signals are sent to the monitor similarly to interlaced video sources, setting this selection to PsF allows the monitor to display such PsF sources as progressive on screen.
Improvements to HLG operation, especially for XMP310. Changes take effect after updating and running new AutoCal. If you do not have time to run a new AutoCal you can still benefit from these improvements by selecting AutoCal Data Backup -> Data 1, then AutoCal Data Load -> Data 1, but a new AutoCal run will maximize the improvements implemented in this build.
XMP550 |
2.4.68 | 11.13.2024 |
View Prerequisites Before Updating
Take Me Directly To The Latest Firmware
Big improvements to interlaced video monitoring capabilities for all XMP models providing high quality, reference grade monitoring of interlaced video signals. There are now 3 deinterlace toggles to choose from:
Interfield: fields are combined and shown as progressive.
Intrafield: fields are shown as interlaced on screen with proper temporal field order. This is the mode suggested for QC monitoring of interlaced sources as it will allow you to spot issues like field reversals.
Psf: for use with progressive segmented frame (PsF) signals. PsF signals are sent to the monitor similarly to interlaced video sources, setting this selection to PsF allows the monitor to display such PsF sources as progressive on screen.
Improvements to HLG operation, especially for XMP310. Changes take effect after updating and running new AutoCal. If you do not have time to run a new AutoCal you can still benefit from these improvements by selecting AutoCal Data Backup -> Data 1, then AutoCal Data Load -> Data 1, but a new AutoCal run will maximize the improvements implemented in this build.
XMP650 |
2.4.68 | 11.13.2024 |
Big improvements to interlaced video monitoring capabilities for all XMP models providing high quality, reference grade monitoring of interlaced video signals. There are now 3 deinterlace toggles to choose from:
Interfield: fields are combined and shown as progressive.
Intrafield: fields are shown as interlaced on screen with proper temporal field order. This is the mode suggested for QC monitoring of interlaced sources as it will allow you to spot issues like field reversals.
Psf: for use with progressive segmented frame (PsF) signals. PsF signals are sent to the monitor similarly to interlaced video sources, setting this selection to PsF allows the monitor to display such PsF sources as progressive on screen.
Improvements to HLG operation, especially for XMP310. Changes take effect after updating and running new AutoCal. If you do not have time to run a new AutoCal you can still benefit from these improvements by selecting AutoCal Data Backup -> Data 1, then AutoCal Data Load -> Data 1, but a new AutoCal run will maximize the improvements implemented in this build.
Updating to current firmware from firmware 2.4.21 or earlier has two very specific prerequisites, please read and understand these before attempting to update:
Before updating please make sure to set the LUM selection on the monitor to 100. Do NOT leave LUM set to 1800 as your monitor will boot to a black screen after update if you do so.
Updating to current firmware from any firmware version prior to 2.4.22 will require you to run a new Direct Connect Volumetric AutoCal after update. Please do not update unless you have the necessary equipment on hand to run a new AutoCal. Rolling back to an older firmware version will not work once you have updated so please make sure to heed this warning.
LM-0750W |
1.1.04-2249 | 06.14.2018 |
LM-0950W |
1.1.04-2249 | 06.14.2018 |
LM-1760W |
1.1.04-2249 | 06.14.2018 |
LM-1770W |
1.1.04-2249 | 06.14.2018 |
LM-2130W |
9.45-1780 | 10.17.2012 |
Updated TWC SAFETY Marker, replaced old TWC marker
Added 16x9 in 4x3 marker for HD signals
Shows box outline of 16x9 portion of a 4x3 cutout of an HD video signal
LM-2140W |
1.1.04-2249 | 06.14.2018 |
LM-2340W |
1.1.04-2249 | 06.14.2018 |
LM-2340TD |
1.1.04-2249 | 06.14.2018 |
LM-2430W |
9.45-1780 | 10.17.2012 |
Updated TWC SAFETY Marker, replaced old TWC marker
Added 16x9 in 4x3 marker for HD signals
Shows box outline of 16x9 portion of a 4x3 cutout of an HD video signal
LM-2450W
|
1.1.04-2249 | 06.14.2018 |
LM-2450W
|
1.1.04-2249 | 06.14.2018 |
LM-2452W
|
1.1.04-2249 | 06.14.2018 |
LM-2452W
|
1.1.04-2249 | 06.14.2018 |
LM-2453W
|
1.1.04-2249 | 06.14.2018 |
LM-2453W
|
1.1.04-2249 | 06.14.2018 |
Adds Sundance Marker.
Download Platform Update
Perform first if using firmware older than 9.50-1866. Includes Firmware Version 9.50-1866 and corresponding CFE Update. This firmware and CFE update can take up to 45 minutes to complete. Please allow for additional time before beginning the platform update. Perform the Firmware Update before the CFE Update in this package. This CFE update consists of a "code.bin" file and several .dat files.
LM-2460W |
1.1.04-2249 | 06.14.2018 |
Adds Sundance Marker.
Download Platform Update
Perform first if using firmware older than 9.50-1866. Includes Firmware Version 9.50-1866 and corresponding CFE Update. This firmware and CFE update can take up to 45 minutes to complete. Please allow for additional time before beginning the platform update. Perform the Firmware Update before the CFE Update in this package. This CFE update consists of a "code.bin" file and several .dat files.
LM-2461W |
1.1.04-2249 | 06.14.2018 |
Adds Sundance Marker.
Download Platform Update
Perform first if using firmware older than 9.50-1866. Includes Firmware Version 9.50-1866 and corresponding CFE Update. This firmware and CFE update can take up to 45 minutes to complete. Please allow for additional time before beginning the platform update. Perform the Firmware Update before the CFE Update in this package. This CFE update consists of a "code.bin" file and several .dat files.
CM-170W |
1.1.04-2249 | 06.14.2018 |
Adds Sundance Marker.
Download Platform Update
Perform first if using firmware older than 9.50-1866. Includes Firmware Version 9.50-1866 and corresponding CFE Update. This firmware and CFE update can take up to 45 minutes to complete. Please allow for additional time before beginning the platform update. Perform the Firmware Update before the CFE Update in this package. This CFE update consists of a "code.bin" file and several .dat files.
All BoxIO |
1.70 | 1.4.2022 |
Adds stand alone time code capture capability for integration partners.
Resolves bug from 1.68 and 1.69 that could cause connectivity issues with older BoxIO devices.
Please read update instructions carefully before attempting an update. If you have any questions about the update process or firmware releases please contact us by email or by phone at +1.678.835.4934.
Updates will not delete calibration or DIT LUTs, but please take note of any custom settings on your monitor as these may be reset during a firmware update.
XMP Series Update Instructions Video
DM Series Update Instructions Video
AM | BM | CM | LM Series Update Instructions Video
BoxIO Update Instructions Video
We highly recommend using the Mass Storage Update Process and not the traditional update process listed below. However, the traditional update process is required if one of the following is true:
1. Your monitor does not already have firmware version 9.16 later. All monitors with firmware versions before 9.16 must be updated using the traditional update process. This will only be required once. After updating to firmware version 9.16 or later all future updates will be possible via the Mass Storage Update process.
2. You have loaded the incorrect firmware (for a different monitor model) into your monitor. You will need to restore your monitor one time using the traditional update process.
Certain DLL files are required for the traditional update program to run correctly. These files are typically included in a normal Windows Installation. However, if you receive warning messages that required DLL files are missing simply download this ZIP file, extract all the files within the folder, and copy/paste them to the C:/Windows/System32 Folder.
Date | Version | For | Notes |
---|---|---|---|
11.29.2024 | 2.0.00-2379 | DM Series | Update to Fast Mode operation when no signal is present: with fast mode function turned on, if no signal is present, the monitor will now automatically disable fast mode to provide you with access to menus. Provided the Fast Mode function remains activated Fast mode will automatically reenable when a signal is present again. This update also fixes a bug from the previous build where booting the monitor with no signal present while fast mode was still active from last session would cause a no menu/no image condition even when the signal was reconnected. |
11.13.2024 | 2.4.68 | XMP Series | Big improvements to interlaced video monitoring capabilities for all XMP models providing high quality, reference grade monitoring of interlaced video signals. There are now 3 deinterlace toggles to choose from: Interfield: fields are combined and shown as progressive. Intrafield: fields are shown as interlaced on screen with proper temporal field order. This is the mode suggested for QC monitoring of interlaced sources as it will allow you to spot issues like field reversals. Psf: for use with progressive segmented frame (PsF) signals. PsF signals are sent to the monitor similarly to interlaced video sources, setting this selection to PsF allows the monitor to display such PsF sources as progressive on screen. Improvements to HLG operation, especially for XMP310. Changes take effect after updating and running new AutoCal. If you do not have time to run a new AutoCal you can still benefit from these improvements by selecting AutoCal Data Backup -> Data 1, then AutoCal Data Load -> Data 1, but a new AutoCal run will maximize the improvements implemented in this build. |
11.08.2024 | 2.4.66 | XMP Series | Resolves protocol conflict with DM series. |
10.29.2024 | 2.4.65 | XMP Series | New Scaling Engine: change to high-quality, ultra-low-latency, bicubic scaling engine for greatly improved HD video monitoring. Updated LUM selection on XMP310 to no longer allow for 1800 preset to be selected as monitor is limited to 1000nits. |
10.21.2024 | 2.4.62 | XMP Series | Adds support for custom marker deletion. |
9.30.2024 | 2.4.60 | XMP Series | Restores Look LUT support that was unavailable in Public Beta 2.4.59. Adds Custom Marker Upload support. Upload any custom 1920x1080 resolution PNG to the monitor. Requires IPRU version 1.9.6 or later, see user manual for details. Adds support for Minolta CA527 to GaiaColor AutoCal. DP In Port activated for secondary use as a computer monitor. This input only supports 3840x2160@60P. Various bug fixes. |
9.19.2024 | 2.4.59 | XMP Series | Official shipping release is still firmware 2.4.50
Adds Custom Marker Upload support. Upload any custom 1920x1080 resolution PNG to the monitor. Requires IPRU version 1.9.6 or later, see user manual for details. Adds support for Minolta CA527 to GaiaColor AutoCal. DP In Port activated for secondary use as a computer monitor. This input only supports 3840x2160@60P. Various bug fixes. NOTE: This firmware build does not support Look LUT upload or connection to LiveGrade. For operators utilizing the Look LUT feature or direct LiveGrade connection to XMP series monitors please continue to use firmware 2.4.50 for now, which will work with LiveGrade provided your source is HD. This functionality will be restored in build 2.4.60 and later. |
7.15.2024 | 2.0.00-2374 | DM Series | Adds 1.5x, 1.66x, and 1.8x anamorphic desqueeze modes. Add Anamorphic Factor toggle to Video menu with options for 1.3x, 1.5x, 1.66x, 1.8x, and 2.0x. Updates Anamorphic Desqueeze operation with toggles for Off, Standard, and Magnified, accessible both from the Video Menu or by assigning anamorphic desqueeze to a function button. The magnified desqueeze mode will apply the selected anamorphic factor and zoom in on the image until the monitor’s 16:9 raster is filled. |
6.28.2024 | 2.4.50 | XMP Series | This is a reissued version of firmware 2.4.49 with the beta 4x Look / DIT LUT support, introduced in fw 2.4.45, but absent from firmware 2.4.47 and 2.4.49, added back in. |
6.27.2024 | 2.4.49 | XMP Series | Resolves YCbCr -> RGB matrix coefficient bug that would only occur if monitoring 422 YCbCr signals with monitor gamut set to 2020 and also toggling inputs. The correct matrix coefficient for 422 signals, based on the monitor’s selected gamut, is now retained even when inputs are toggled. Improves performance of Video Range (64-940) gamma EOTF tracking. Improvements are automatically applied if running a new AutoCal. If not running a new AutoCal after update please manually refresh calibration LUT generation from the monitor’s Color Menu by selecting AutoCal Data Backup -> 1, AutoCal Backup Load -> 1. |
6.20.2024 | 2.4.47 | XMP Series | Improvement to GaiaColor AutoCal LUT generation algorithms for better saturation preservation in extreme lowlights leading to even lower dE values, especially at mesopic luminance levels.
Note: new LUT generation algorithm automatically applied with next AutoCal run or can be manually initiated without requiring recalibration from monitor’s Color menu by selecting AutoCal Data Backup -> 1, then selecting AutoCal Backup Load -> 1. Once selected LUTs will be refreshed using updated algorithm based on last AutoCal profiling data set. Resolves panel self test sequence bug on XMP650 inadvertently introduced in fw build 2.4.45. Changes the default Luminance Custom Value from 160 to 100. This has no impact on luminance unless Luminance Mode is set to Custom. |
6.5.2024 | 2.4.45 | XMP Series | Adds 3G/HD_INx4 function for quick single button access to quad view mode. Note, signals must be synchronized, see user manual for details. Adds Smooth Gradient function enabling reduced quantization and improved perceived smoothness of gradients, especially when dealing with high bit depth PQ EOTF signals. Bug fix for XMP310, adds 720P signal support. Beta 4x Look / DIT LUT support - for limited testing, official Look LUT update still to come. Currently limited to HD sources for testing. Update to panel frequency sync behavior for interlaced sources to prevent overflow condition. Note, this disables the Mode1 and Mode2 de-interlace toggle for now, monitor will always process as Mode 1 regardless of toggle setting. An improved interlaced video processing mode is expected at a future date. |
3.28.2024 | 2.4.41 | XMP Series | Adds support for Klein K10A and K80 colorimeters to GaiaColor AutoCal. |
3.18.2024 | 2.4.40 | XMP Series | Bug fix for audio de-embedding distortion
Bug fix for XMP310 distorted image in quadrant 3 of quad 3G / 1.5G display mode. Adds support for i1D3DS OEM, CA210(10mm), CA310(10mm), and CA410 to GaiaColor Direct Connect Volumetric AutoCal. |
3.4.2024 | 2.4.38 | XMP310 | Adds automatic CPN prompt to XMP310
Adds pixel mapping support for HD, 2K, and 4K signals on XMP310 |
02.06.2024 | 2.4.35 | XMP Series | Restores functioning HLG EOTF selections that were inadvertently disabled in previous firmware build.
3rd Party LUT Mode simplified: removes Advanced/Normal toggle within 3rd Party LUT Mode. Normal mode is now the standard operating mode. Monitor’s LUM Selection can now be used in 3rd Party LUT Mode. Make sure that where you have LUM selection set before building a LUT is where you leave LUM selection set when using that LUT. General GaiaColor AutoCal calibration improvements/enhancements. Fixes intermittent freeze on boot up behavior. |
12.8.2023 | 2.4.25 | XMP550 | Adds ability to turn keypad LED lights Off. This new option can be found on the System Menu -> Button LED. Please note that to prevent confusion on power cycle the keypad lights reset to ON whenever the monitor is rebooted. |
12.01.2023 | 2.4.24 | XMP550 | Updating to firmware 2.4.24 from firmware 2.4.21 or earlier has two very specific prerequisites, please read and understand these before attempting to update: Before updating please make sure to set the LUM selection on the monitor to 100. Do NOT leave LUM set to 1800 as your monitor will boot to a black screen after update if you do so. Updating to 2.4.24 from any firmware version prior to 2.4.22 will require you to run a new Direct Connect Volumetric AutoCal after update. Please do not update to 2.4.24 unless you have the necessary equipment on hand to run a new AutoCal. Rolling back to an older firmware version will not work once you have updated to 2.4.24 so please make sure to heed this warning. DCVA Updates: CPN Update: |
11.28.2023 | 2.0.00-2372 | DM211 & DM231 | Sets default I->P mode to Inter-field on DM211 and DM231. |
11.20.2023 | 2.4.17 | XMP550 | GUI Update: Adds menu brightness adjustment selection to OSD menu allowing onscreen menu to be dimmed according to user’s preference. |
11.13.2023 | 2.4.15 | XMP550 | DCVA (Direct Connect Volumetric AutoCal) improvements including: Addition of automated warmup routine to DCVA process eliminating need to perform a separate manual warmup before starting calibration. See updated AutoCal guide for details. Improvements to loading behavior. Provides for even greater consistency between L20 and larger test patch sizes (e.g. L32 / L40) even through a 1,000nit threshold. Further improvements to extreme lowlight tracking, building on version 2.4.11’s luminance tracking improvements, with a specific focus on greater chromaticity neutrality. Removes the Delete AutoCal Data menu item as this is not needed. Adds AutoCal Data Backup and AutoCal Backup Load menu items. These are not needed for normal use cases and have been added primarily to facilitate probe integration testing internally at FSI. |
10.23.2023 | 2.4.11 | XMP550 | Improvements to PQ luminance tracking in lowlights. |
- | 2.4.10 | XMP550 | UI Update: Adds LUM 1800 Selection.
UI Update: LUM Custom Slider Now Expanded to allow selections up to 2000. UI Update: Adds menu selections for baud rate, parity, and address to enable use with RS422/485 remote control interfaces. Adds support for HLG in Video Range at 1800nits peak. |
10.13.2023 | 2.4.09 | XMP550 | Fixes bugs from previous builds that would offset 3rd party LUT memory loading by one position. 3rd Party LUTs now load to the expected memory slots. Adds correct HLG Extended Range (64-1019) monitoring option. |
10.9.2023 | 2.4.08 | XMP550 | UI Update: Extended Range (64-1019) SDR selections (any selection using Gamma EOTF) will now use the monitor’s LUM selection as the nominal (code value 940) luminance target, not the peak white luminance target. This enables switching between Video (64-940) and Extended (64-1019) while retaining the same nominal white luminance. Bug Fix: HLG selections now use correct system gamma for any selected peak luminance setting. |
- | 2.4.07 | XMP550 | Bug Fix: SDI Format configuration now follows Payload ID detection when set to AUTO. If the signal’s Payload ID is present and correct leaving SDI Format set to AUTO should allow the monitor to automatically set SDI Format to match 10 and 12bit YCbCr or RGB signals. If signal is missing Payload ID or Payload ID is incorrect you can still use the manual SDI Format toggle to set SDI Format as needed. |
- | 2.4.06 | XMP550 | Bug Fix: Panel Refresh. 24P, 48P -> 96Hz 25P, 50P -> 100Hz 30P, 60P -> 120 Hz UI Update: Load Profile -> Default. Has been updated to use 6500K as default CCT. UI Update: AutoCal probe positioning crosshair. Guide position adjusted to exact center of display. |
10.3.2023 | 2.4.05 | XMP550 | Fixes UI bug that advised naming the CR100 matrix (null) when running AutoCal, now correctly advises that name of CR100 matrix must be XMP550 |
5.5.2023 | 2.0.00-2370 | DM Series | Adds recovery / bypass mode for black screen, slow data save, and other unwanted monitor states that can occur if AutoCal is interrupted or done incorrectly (e.g. probe lens covered). All DM series users are advised to update to this build or later to ensure the availability of the recovery mode should it ever be needed. Adds 2.39:1 & 2:1 Combo Custom Marker |
4.12.2023 | 2.0.00-2365 | DM Series | Adds 1.78 for Square Custom Marker Fixes intermittent requirement to update DM160 firmware twice, just a single update is now sufficient. |
3.9.2023 | 2.0.00-2363 | DM160 | Fixes potential small white balance shift on DM160 when monitoring 25 / 50 frame rate signals (fixes for both Fast and Normal Mode) |
3.7.2023 | 2.0.00-2362 | DM160 | Fixes potential small white balance shift on DM160 when monitoring 25 / 50 frame rate signals. |
2.27.2023 | 2.0.00-2360 | DM160 | Resolves bug that could cause intermittent image artifacts when monitoring PsF signals. |
12.5.2022 | 2.0.00-2358 | DM Series | Adds direct support of Colorimetry Research CR250 and CR300 spectroradiometers to DM series AutoCal. See updated AutoCal guide for details.
Resolves bug from FW2.0.00-2356 / 7 that may have made the firmware build incompatible with some DM211 units. |
11.27.2022 | 2.0.00-2356 | DM Series | Adds direct support of Colorimetry Research CR250 and CR300 spectroradiometers to DM series AutoCal. See updated AutoCal guide for details. |
11.15.2022 | 2.0.00-2355 | DM Series | Greys out / disables the gamma selection on the Color Management Menu when an HDR Preview mode is selected to avoid confusion. |
10.26.2022 | 2.0.00-2352 | DM220 | Improvements to fast mode performance for 25P frame rates. |
10.26.2022 | 2.0.00-2350 | DM Series | Resolves intermittent line on right side of image with 3G Level A 444 RGB signals while Fast Mode is active. |
10.17.2022 | 2.0.00-2351 | DM220 | Adds unrestricted support for 24P in Fast Mode.
Removes FM24 menu option, no longer required. Various other improvements to fast mode performance for 24P and 30P frame rates. |
10.17.2022 | 2.0.00-2349 | DM Series | Restores 1D DIT (Look) LUT capability that was inadvertently made inaccessible in a previous build. |
10.4.2022 | 2.1.25 | XM Series | Updates to 1.5G and 3G signal support. When Video Menu-> SDI Format -> AUTO is selected payload ID of the signal will be detected and followed. If Payload ID is missing from the output device the monitor will process the incoming signal as 4:2:2 YCbCr when set to AUTO, but this update allows the SDI Format Selection override (Video Menu-> SDI Format -> manual selection) to also work on 1.5G and 3G signals, not just 6G and 12G signals. |
9.23.2022 | 2.0.00-2348 | DM Series | Significant update to AutoCal for improved perceptual lowlight performance, especially on LCD models. An optional Mesopic Optimization toggle has been added to the Color Management menu. When enabled this mode can improve visual performance below photopic luminance ranges by incorporating an accommodation for mesopic spectral sensitivity functions. Enabling or Disabling the Mesopic Optimization toggle does not require recalibration, as with other Color Management menu selections LUTs will be calculated on an as needed basis from the stored AutoCal profiling data. Bug fix for potential black screen output after AutoCal on some units manufactured after August of 2022. |
9.22.2022 | 2.0.00-2345 | DM Series | Significant update to AutoCal for improved perceptual lowlight performance, especially on LCD models. An optional Mesopic Optimization toggle has been added to the Color Management menu. When enabled this mode can improve visual performance below photopic luminance ranges by incorporating an accommodation for mesopic spectral sensitivity functions. Enabling or Disabling the Mesopic Optimization toggle does not require recalibration, as with other Color Management menu selections LUTs will be calculated on an as needed basis from the stored AutoCal profiling data. |
9.15.2022 | 2.0.00-2343 | DM241 | Significant update to AutoCal for improved perceptual lowlight performance, especially on LCD models. A mesopic optimization has been incorporated in the AutoCal routine for improved visual performance below photopic luminance ranges. To take advantage of this enhanced AutoCal routine please both update your monitor and run a new AutoCal as the previous AutoCal results will continue to be used until a new AutoCal is run. A future firmware release will add the ability to enable or disable this mesopic optimization, the current release is with this optimization enabled only. |
1.19.2022 | 2.0.00-2327 | DM241 | Reverts default to inter-field selection for I->P mode for DM241. |
1.6.2022 | 2.0.00-2326 | AM211P, BM211, BM241, BM420, BM550, DM170, DM240, DM241, DM250 | Resolves possible ethernet connection bug on some units. |
1.4.2022 | 1.70 | BoxIO | Adds stand alone time code capture capability for integration partners. Resolves bug from 1.68 and 1.69 that could cause connectivity issues with older BoxIO devices. |
12.15.2021 | 2.0.00-2325 | DM Series | Increases AutoCal patch size on DM170 for improved K10A compatibility. Adds i1d3 to DM250 AutoCal probe selection list. |
10.19.2021 | 1.68 | BoxIO | This firmware build can be used on all BoxIO devices. For BoxIO serial numbers greater than B101A02237 this firmware or later is required. Please do not roll back these newer units to firmware before this 1.68 build, it will render your BoxIO inoperable. Adds support for frame callback in 0-1023 Full Range 444 RGB mode. |
7.19.2021 | 2.0.00-2319 | DM170 & DM240 | Adds check / protection for loading incompatible older firmware versions. |
7.6.2021 | 2.0.00-2318 | DM170 & DM240 | Adds AutoCal support for Klein K80. |
6.23.2021 | 2.0.00-2317 | AM | Resolves bug that prevented log modes from working correctly when monitor was set to 6500K 2.4 gamma. |
6.17.2021 | 2.1.22 | XM | Resolves bug from build 2.1.20 that could prevent USB port from working. Resolves intermittent display of yellow line that could occur when booting XM OLEDs in normal mode. |
6.7.2021 | 2.1.20 | XM | Unifies build for all XM models. Saved profile configurations can now be loaded via function button. See user manual for details. |
6.2.2021 | 2.0.00-2314 | DM170 & DM240 | Fixes onscreen prompt typo when selecting CR100 for AutoCal. |
6.2.2021 | 2.1.19 | XM | Profile and Profile Set replaced with simpler Profile Save and Profile Load menu options. Default Configuration added providing way to reload factory default settings on monitor. See user manual for details. Preliminary DisplayPort support for testing on XM310K & XM311K only. Not all DisplayPort sources will be supported. For those testing we would greatly appreciate your findings, whether working or not working. When submitting feedback please let us know what OS and Graphics Card you are using. Note: DisplayPort on XM310K is currently only compatible with static backlight selections. |
5.19.2021 | 2.0.00-2313 | DM170 & DM240 | Adds AutoCal support for X-Rite i1D3 OEM probes (requires probe firmware 2.29c + proper display matrices - contact FSI for details)
Adds AutoCal support for Minolta CA410 Adds support for Harris VTM-4100 1024x768 DVI output |
4.14.2021 | 2.0.00-2309 | AM211 & BM211 | Adds Tetrahedral LUT Interpolation. |
3.15.2021 | 2.0.00-2305 | DM Series | Adds model number check and firmware mismatch warning. Only becomes active after this update, but for all future firmware updates the monitor will now provide an onscreen warning if you are trying to load a firmware version that does not match with the model number indicated on the system menu.
Monitor will now display an “Update Failed. No LUT file found!” error message if trying to load a cLUT with invalid names. Valid names are user1, user2, and user3. |
3.4.2021 | 2.0.00-2303 | DM Series | Luminance, RGB Gain/Bias, and other selectable value changes can now be quickly cancelled and returned to previous setting by pressing Menu. To confirm a selection value change press Enter. Resolves intermittent DCI P3 + Gamma 2.6 selection bug. |
2.23.2021 | 2.0.00-2300 | DM Series | Resolves custom luminance selection bug on DM250. Set luminance to desired value and press enter to confirm. |
2.10.2021 | 2.0.00-2299 | DM Series | AutoCal Calibration now faster (7 to 8 minutes total) as LUTs are now only generated on demand from saved measurement data when a new Gamut, EOTF, CCT combination is used for the first time. This saves considerable time by not calculating and saving LUTs for the wide variety of potential configurations you may not otherwise use. Resolves Fast Mode Bug on DM250 Allows for better calibration optimization to a desired frame rate on DM250 Known Bug (DM250 Only): The Custom Luminance Slider is not working as intended. We are working on a fix for this bug. Custom selections can still be made using this specific workaround: Set Luminance Mode to Custom, Move Luminance slider to desired peak luminance selection, Set Luminance Mode to Standard, then set back to Custom to calculate and activate the new setting. Changing the custom luminance slider and then performing any other action besides that listed above may lock you out of the menu. If this happens simply hold down the power button to reboot the monitor. The Standard, Studio, and Outdoor Luminance selections continue to operate normally and are not impacted by this bug. |
2.05.2021 | 2.0.00-2295 | DM250 | Updates to Display Port / DVI inputs for improved stability and signal support from various DVI/DP sources.
Improvements to luminance control toggles on LCD units when both 3D and 1D LUTs are bypassed. DM250 Known bug: calibration is deactivated in “fast mode.” We are working on a fix for this bug. |
1.13.2021 | 2.1.10 | XM Series | Resolves flashing lines bug for 12bit UHD/4K signals sent over 12Gbps or Dual 6Gbps SDI. 12bit signals now supported over 12G and Dual 6G SDI in addition to Quad 3G SDI.
Resolves Look/DIT LUT support bug that could cause distorted image and/or line on side of image when look LUT was activated. |
1.11.2021 | 2.0.00-2292 | DM Series | Updates to Display Port / DVI inputs for improved stability and signal support from various DVI/DP sources.
Improvements to luminance control toggles on LCD units when both 3D and 1D LUTs are bypassed. DM250 Known bug: calibration is deactivated in “fast mode.” We are working on a fix for this bug. |
1.08.2021 | 1.63 | BoxIO | Addresses intermittent bug that could cause BoxIO to hang/crash in a very small percent of cases when switching from single to dual channel. |
1.04.2021 | 2.1.9 | XM Series | LUT Interpolation now permanently set to tetrahedral. Trilinear removed from menu.
Resolves intermittent flashing screen on some XM310K when no signal present. |
1.04.2021 | 1.62 | BoxIO | LUT Interpolation now permanently set to tetrahedral.
Fix for SMPTE372M Dual-Link SDI Audio Channel bug. Audio channels will now pass correctly on both processed and clean loops. Improved Dual Channel performance, addresses intermittent bugs that would previously manifest in Dual Channel + trilinear mode. This firmware should be used with IPRU build 1.8.6 or later. |
12.04.2020 | 2.0.00-2288 | DM Series | Adds AutoCal support for DM Series monitors. |
11.02.2020 | 2.1.8 | XM Series | Adds static IP address capability.
Resolves potential luminance level bug on XM OLED firmware 2.1.7. |
09.14.2020 | 2.1.7 | XM Series | Adds static IP address capability. |
05.22.2020 | 2.1.3 | XM310K & XM311K | Fixes bug that may have intermittently prevented processed MON SDI output from working if signal cable was connected before monitor was powered on. |
05.11.2020 | 2.1.2 | XM310K & XM311K | Fixes bug that could potentially prevent video from displaying or displaying correctly if monitor booted without signal connected. Other minor bug fixes. |
04.21.2020 | 2.0.01 | XM310K | Greatly enhanced support for 3rd party calibration LUTs in Dynamic (modulated backlight) Luminance Modes. Users may now utilize the Dynamic Luminance Mode directly from the USER, LightSpace, and CalMAN Color System selections. Updates to GaiaColor Color System selection, now supports static luminance modes (e.g LUM100) in addition to the previously supported Dynamic Luminance Modes. Vastly improved Peak Mode optimized backlight algorithms for all Color System selections. |
04.07.2020 | 1.88 | XM310K | Greatly enhanced support for 3rd party calibration LUTs in Dynamic (modulated backlight) Luminance Modes. User may now utilize the Dynamic Luminance Mode directly from the USER, LightSpace, and CalMAN Color System selections. The Look LUT position no longer needs to be used to support customized calibration LUTs in modulated backlight operation. Auto disable of Back1D LUT position when in Dynamic LUM mode. Auto access/enable of Back1D LUT in Static LUM modes. Auto toggle of NORMAL LUT Mode if Dynamic LUM Mode activated (Dynamic only supported in Normal Mode). When calibration LUTs are set to unity in Dynamic LUM mode within USER, LightSpace, or CalMAN Color System users will have true native color gamut response for profiling. EOTF and peak luminance behavior are governed by baseline EOTF selection calibrated as part of closed loop autocal routine. |
03.24.2020 | 1.85 | XM310K | Resolves bug that may have required reselection of EOTF if switching from one gamut option to another with the same primaries while in GaiaColor mode |
03.20.2020 | 1.84 | XM310K | Vastly Improved Peak Optimized Modulation Mode Algorithms Ability to assign Modulation Modes to Function Keys. Note, monitor will default to modulation mode set on Video Menu if an alternate modulation mode is not activated via function button Resolved some AWB process bugs Resolved some Function Button response bugs Known Bug, when in GaiaColor Mode static LUM Mode selections (e.g. LUM 100, 200, etc.) may show a full white screen. For static backlight use and to avoid this issue please switch to Default, CalMAN, or LightSpace. |
12.18.2019 | 1.75 | XM OLEDs | Resolves bug on XM OLED units that could render monitor inoperable if switching Color System to GaiaColor with certain EOTF selections active. |
12.03.2019 | 1.60 | BoxIO | Resolves bug that could cause potential loss of timecode with frame capture when input signal condition changes. |
12.02.2019 | 1.1.74 | XM Series | Added 444 RGB signal support to Waveform & Vector Scope Added two additional user configuration memory positions, 5 total now. User configurations now save rotary knob settings. |
12.02.2019 | 1.1.04-2254 | DM Series | Maintenance update for select units. |
11.20.2019 | 1.1.04-2253 | DM Series | Resolves potential fast mode bug introduced in 1.1.04-2252. |
11.07.2019 | 1.1.04-2252 | DM Series | Replaces trilinear LUT interpolation with improved tetrahedral LUT interpolation. |
10.30.2019 | 1.71 | XM Series | Fixes Advanced Mode 422 color bug. XM310K - Requires new AWB calibration after update if updating from firmware older than 1.1.69. |
10.23.2019 | 1.70 | XM Series | Adjusted resynchronizing behavior with unclean source switching. Monitor will display black until synced to new source. XM310K - Requires new AWB calibration after update if updating from firmware older than 1.1.69. |
10.18.2019 | 1.69 | XM310K | Greatly improved HLG performance. Requires new AWB calibration after update. Contact support for additional details. |
8.19.2019 | 1.58 | BoxIO | Solves frame capture without timecode bug. |
7.31.2019 | 1.1.04-2251 | DM170 | Changes I->P default setting to Inter-Field on DM170. |
7.31.2019 | 1.1.04-2250 | DM240 | Changes I->P default setting to Inter-Field on DM240. |
7.22.2019 | V1.1.65 | XM Series | Support for remote control via IP Remote Utility (Version 1.7.1 for Mac/PC and 3.3 for iOS or newer required) Function buttons now reassignable. |
7.11.2019 | V1.1.63 | XM Series | Markers have been moved to OSD menu. OSD Menu now has “Menu Set” option allowing menu to automatically disappear after 5s, 10s, or to stay On until manually cleared. When you toggle Markers On/Off from Function menu the Marker Menu item reflects the status correctly. |
7.2.2019 | V1.1.62 | XM Series | Allows function buttons to be reassigned. |
6.10.2019 | V1.1.61 | XM Series | Adds Lum Coloring (Customizable Exposure Check) function - BETA |
5.23.2019 | 1.57 | BoxIO | Resolves cold boot without signal bug introduced in firmware 1.56. Resolves dual channel range reporting bug. Requires IPRU 1.6.9 on MacOS and Win or 3.0 on iOS. |
5.20.2019 | V1.1.59 | XM Series | Fixes bug introduced in 1.1.58 that prevented Clear Panel Noise process from running on XM OLEDs. Fixes bug introduced in 1.1.58 that prevented access to AWB data reset. |
5.3.2019 | V1.1.58 | XM Series | Adds HDR (PQ) Waveform - BETA (only works with YCbCr formats) - From Scope menu select LUM Style HDR or IRE Updates scopes to allow graticules and traces to automatically match monitor’s current signal range selection (set in Video Menu). Adds Fan Speed Control toggle to System Menu for XM311K. Debugs XM310K 59.94 input signal handling. Addresses irregular vertical jump bug when monitoring interlaced signals. Adds 1:1 Pixel Mapping Option (set in Video Menu). |
4.15.2019 | 1.56 | BoxIO | Adds support for Tetrahedral LUT Interpolation. Trilinear LUT Interpolation may still be selected. Requires IPRU 1.6.7 on MacOS and Win or 3.0 on iOS. |
1.28.2019 | V1.1.54 | XM Series | Adds LUT Interpolation selection. Choose from trilinear or tetrahedral. Tetrahedral is recommended.
Resolves bug where pressing down on rotary knob if previously set to selection of -50 would not reset knob control to default. Improves functionality of user configuration options and resolves some user configuration bugs. P3-D65-ST2084 renamed to P3-ST2084. On XM310K in GaiaColor mode please note that you must select 6500K as your Color Temperature for a D65 white point when P3-ST2084 gamut is selected. |
1.08.2019 | V1.1.51 | XM Series | Adds ability to save and load user profiles.
Changed name of P3-ST 2084 gamut selection to P3-D65-ST 2084. XM310K: Resolves intermittent startup bug (dark rectangle top left in Dynamic backlight mode). OLED Units: Resolves 4K / Quad SDI Bug. Changes name of ColorSpace: User to ColorSpace: Default. |
12.07.2018 | V1.1.48 | XM310K | Adds 12bit display performance when in Dynamic backlight mode. |
12.07.2018 | V1.1.47 | XM310K | Update to Signal ID Window functionality, you can now press the active input button to recall the Signal ID window at any time. CineColor ColorSystem renamed GaiaColor. Updates to EOTF and ColorTemp display when in modes other than GaiaColor, will now always say default in User, LightSpace, and CalMAN modes to avoid confusion. Luminance Mode Default Now set to 100 instead of custom after update. Addresses bug that could cause a momentary bright onscreen flash with transitions from full black to a dark, but visible, scene while in Dynamic Luminance Mode. |
12.06.2018 | V1.1.48 | XM OLED | Addresses bug that used Unity 1D LUT instead of saved Post 1D LUT when switching to LUM HDR mode on XM OLED units. |
11.28.2018 | V1.1.46 | XM310K | Rotary knob positions are now saved through a power cycle. ColorTemp / EOTF selections now locked out in ColorSystems where these selections are not applicable. Factory AWB now password protected. Minor bug fixes to signal ID window operation. Improved support for 720P signal formats. Minor bug fixes to cal sensor access / communication. LUM selections of Dynamic Char and Dynamic Motion Opt consolidated into single selection called Dynamic. |
11.28.2018 | V1.1.46 | XM OLED | Rotary knob positions are now saved through a power cycle. ColorTemp / EOTF selections now locked out in ColorSystems where these selections are not applicable. Factory AWB now password protected. Minor bug fixes to signal ID window operation. Improved support for 720P signal formats. Minor bug fixes to cal sensor access / communication. |
11.14.2018 | V1.1.44 | XM310K | AntiFlicker Selection replaced with Optimize Modulation Selection. Optimize Modulation selections of Peak, Motion, and Contrast added. See manual for details. Luminance Mode and Luminance Custom selections updated. General improvement to LED/LCD sync and backlight modulation algorithms. |
10.30.2018 | V1.1.42 | XM Series | XM310K: Adds Signal Status Display - can be set to On, Off, or 5 second display (default). When set to 5 second display signal status will appear only on format changes or when input button is pressed. See manual for details. Adds Status and Menu positioning options allowing these OSD elements to be moved to different areas of the screen. Resolves Dynamic Character Optimization bug introduced in firmware 1.1.40. Improves AWB performance. Adjusts position of AWB crosshair reference. Adds AntiFlicker selection providing optional levels of flicker/shake reduction in high contrast moving images when in Dynamic Backlight Modes on XM310K. All XM Models: Enables Waveform and VectorScope position toggles. |
10.29.2018 | V1.1.41 | XM OLED | Adds Signal Status Display - can be set to On, Off, or 5 second display (default). When set to 5 second display signal status will appear only on format changes or when input button is pressed. See manual for details. Adds Status and Menu positioning options allowing these OSD elements to be moved to different areas of the screen. Panel dimming setting now remembered through power cycle. Moved HDR panel toggle to Luminance menu. |
09.24.2018 | V1.1.39 | XM Series | Resolves HDR enable bug. Adds two deinterlace options. -Mode 1: Combines fields and displays as progressive. -Mode 2: Shows on screen as interlaced with correct field order. Adds incremental luminance slider in 5nit jumps from 45 to 800. |
09.20.2018 | V1.1.38 | XM Series | Resolves intermittent system boot up bug. Adds Klein K80 / K10A integration.* *XM551U, XM651U, XM650U support K80 and K10A. XM310K does not support the K10A, but does support the K80. |
09.05.2018 | V0.1.33 | XM650U | Improves PsF signal support, PsF now shown as progressive on screen. Adds RGB Gain/Bias controls per color space selection. Resolves bug that made it necessary to reselect color space selection after switching in/out of HDR mode. Adds 3G_DL_IN Video Mode Selection. Adds 6G_DL_IN Video Mode Selection. Adds 6G_DL_IN 3G_OUT Video Mode Selection Adds Payload ID to processed (down converted) monitor output. Adds menu items reserved for future use in CineColor Mode only (not currently active): Temperature, HLG-1200, and HLG-3000. These settings are inactive or bypassed in USER, CalMAN, and LightSpace selections. Changes default LUM setting to 100. SDI Format selection overrides payload ID if not set to AUTO. Adds support for waveform and vector scope with interlaced and PsF sources. Adds TPG handles for third party calibration applications. Adds AWB support for CRI CR100 colorimeter. Calman menu item renamed CalMAN. Gamma menu renamed EOTF. Adds 48nit LUM selection. |
08.31.2018 | 0.1.37 | XM310K | PsF signals now automatically shown on screen as progressive. Adds support for waveform and vector scope with interlaced and PsF sources. Adds TPG handles for third party calibration applications. Adds AWB support for CRI CR100 colorimeter. Calman menu item renamed CalMAN. Gamma menu renamed EOTF. |
06.14.2018 | 1.1.04-2249 | AM, BM, CM, DM, LM | Adds Sundance Marker |
06.05.2018 | V0.1.24 | XM650U | Enables rotary knob control. Enables HD downconversion, use Video -> Mode selection to control. Adds basic interlaced video support, further interlaced video improvements planned. Resolves bug that disabled calibration LUT selection when HDR mode was enabled. Adds HLG-2020 gamut position. Adds Payload ID display to System Menu. Adds Factory AWB menu item -> reserved for future use. Adds support for real time LUT manipulation with on set grading software like LiveGrade Pro. |
05.30.2018 | V0.1.54 | BoxIO | Enables complete capture of a metadata stream resolving an earlier issue where not all ancillary data packets were retrievable. Required for ancillary data support in LiveGrade Pro Version 4 |
04.20.2018 | V0.1.18 | XM650U | Scale to fit support added for 720P, 2K and 4K signals. Improved scaling of 1080p signals. Adds panel dimming control, see user manual for details. Increases peak luminance capabilities in HDR mode by approximately 10% compared to firmware version 0.1.15. |
04.16.2018 | 1.1.04-2248 | DM Series | Allows Custom Sharpness to be set while Fast Mode function is active |
04.04.2018 | 1.1.04-2247 | DM Series | Allows Max Sharpness and Fast Mode functions to be used simultaneously |
03.20.2018 | 1.1.04-2246 | All | Adds 9:16 marker |
01.25.2018 | 1.1.04-2245 | All | Adds Discovery V5 marker |
12.27.2017 | 1.1.04-2244 | All | Adds 1:1 marker.
Resolves bug that could cause monitor to freeze if using Column Scope in Window 2 position. |
10.12.2017 | 1.1.04-2242 | All | Adds support for higher frame rate 2048x1080 resolution signals including 47.95P, 48P, 50P, 59.94P, and 60P. |
10.02.2017 | 1.1.04-2238 | All | Adds Lifetime V2 & Discovery V3 Markers. |
09.22.2017 | 1.51 | BoxIO | Adds ScopeStream functionality
Support for new IP Remote Utility 1.0 |
09.06.2017 | 1.1.04-2237 | All | Moves LUT Update and Profile Load dialogs to top of screen for easier use.
Adds Oxygen, Desjardins 1, Desjardins 2 Markers. |
08.18.2017 | 1.1.04-2231 | DM Series | Added Real Time Scopes Menu, RTS settings can now be manipulated through menu as well as rotary knobs.
Added Customizable Multi-Color Real Time Scope settings. Manage through RTS menu. Fixed bug preventing frame capture from working correctly if ScopeStream was used. |
07.10.2017 | 1.1.04-2223 | DM Series | Adds 3rd Generation real-time Focus Assist to DM series monitors with selectable color, intensity, and weight
Adds custom marker: Oxygen Adds automated detection and progressive display of PsF signal formats in both standard and fast monitoring modes Adds support for Fast Mode when using 4:4:4 signal formats Resolves DM240 Fast Mode bugs: image moving 1 line lower and flashing white dot in lower left corner of screen |
06.27.2017 | 1.1.04-2207 | DM Series | Enables ScopeStream
Resolves horizontal bottom line artifact for some patterns and while in fast mode Resolves image/OSD blackout upon startup w/o incoming signal and with monitor still in fast mode Resolves intermittent sparkles when entering fast mode |
05.08.2017 | 1.1.04-2204 | All Monitors | Adds Tele-Quebec Marker Fixes horizontal positioning bug when using fast mode on DM170 |
3.22.2017 | 1.1.04-2202 | All Monitors | Resolves 5K tone audio output when 19.2K tone input is received. |
3.22.2017 | 1.1.04-2198 | DM Series | Adds ability to see active markers underneath translucent and transparent Real Time Scope Modes.
Resolves bug that caused corrupt graticules info window readout in certain graticule positions. Resolves missing image line on DM240 with 1080i signals in NR or Show PsF as Progressive modes. |
2.27.2017 | 1.1.04-2194 | DM Series | Adds New Advanced Real Time Waveform & Vector Scope |
1.9.2017 | 1.45 | BoxIO | Improves Frame Capture Function
Frame Captures with "line artifacts" can be resolved by reselecting current active input Updated Range Selections include: Video, Extended, SMPTE Full, and Full Range Adds Dual-Link (SMPTE ST-372M) signal support Updated OSD Menu Overlay |
11.18.2016 | 1.1.03-2185 | DM Series | Adds HDR Preview mode to DM Series monitors. See user manual for additional details.
Improves backlight dimming performance. |
11.18.2016 | 1.1.03-2181 | DM240 | Resolves Fast Mode bug for DM240 Adds support for markers while Fast Mode is active |
11.03.2016 | 1.39 | BoxIO | Adds support for 2 wire square division 4K. |
10.24.2016 | 1.37 | BoxIO | Added ability to apply LUT unscaled in addition to previous capability of applying only within selected operating signal range.
Added RAW capture format for BoxIO. Frames saved as RAW may be loaded into Frame Callback feature. Added Frame Callback capability in all modes. A frame previously captured in RAW format may now be played out of BoxIO as a full resolution reference frame. Frames can be quickly loaded from a connected computer and up to 16 frames can be loaded to BoxIO’s onboard flash memory as well. Test patch generation bug for Full Range YCbCr levels resolved, 1:1 correspondence in all signal ranges now. Test patch generation modified to respond to ‘Apply LUT’ selection. Please note that when set to ‘within signal range’ BoxIO will clip output at the limits set by the signal range even if no LUT is active. 10% and 5% windows added as options for TPG output Slight horizontal shift in frame capture resolved Overall frame capture performance improved |
09.06.2016 | 1.31 | BoxIO | Fixes Dual Channel Mode relocking glitch after external switching. |
08.30.2016 | 1.30 | BoxIO | Enables LUT capability in TPG mode.
Adds Frame Capture buffer clear when switching modes in application. |
08.19.2016 | 1.26 | BoxIO | Adds Channel 2 Output selection for Mode 2 Channel 1 Input
Improves Frame Capture performance Enables clean pass of ancillary data |
08.16.2016 | 1.1.03-2165 | Monitors | Adds NBC Safety 2016 Marker
DM Series: Enables timecode capture as part of ethernet frame capture protocol. Resolves processed monitor output bug that resulted in vertical line on right side of image with some 3G formats. Resolves intermittent flashing in timecode display for 23.98 and 24P sources. |
08.16.2016 | 1.25 | BoxIO | ** Deprecated, replaced immediately by 1.26 **
Adds Channel 1 Output selection for Mode 2 Channel 2 Input Improves Frame Capture performance Enables clean pass of ancillary data |
08.11.2016 | 1.24 | BoxIO | Improves Frame Capture performance |
08.08.2016 | 1.1.03-2163 | DM Series | Enables timecode capture as part of ethernet frame capture protocol.
Resolves processed monitor output bug that resulted in vertical line on right side of image with some 3G formats. Resolves intermittent flashing in timecode display for 23.98 and 24P sources. |
08.04.2016 | 1.1.03-2162 | AM / BM / CM | Adds NBC Safety 2016 Marker |
08.01.2016 | 1.23 | BoxIO | Adds support for more TPG formats and Window & Full Frame setting. |
07.11.2016 | 1.21 | BoxIO | Adds Apply LUT To settings.
Adds Test Pattern Generation. |
06.28.2016 | 1.1.03-2153 | DM250 | Resolves luminance level bug when using P3 & power cycling the monitor. |
06.16.2016 | 0616 | BoxIO | Changes hardware names displayed in BoxIO Utility.
Changes firmware release version shown in BoxIO Utility. |
06.14.2016 | 0614 | BoxIO | Operation of reset button slightly altered to be easier to use, no longer requires a powercycle to reset BoxIO to factory network settings.
Adds LED Status light operation (see user manual for more details). |
06.08.2016 | 0608 | BoxIO | Resolves minor YCbCr processed out bug. |
06.03.2016 | 0603 | BoxIO | Enables network settings reset. Will return settings to those indicated on BoxIO serial # label. |
05.24.2016 | 1.1.03-2149 | DM250 | Adds Vertical, Horizontal, and Vertical+Horizontal Image Flip feature for both onscreen and downstream display via second screen SDI output.
Set and enable via function key. Toggle between available image flip modes using up/down keys. |
03.22.2016 | 1.1.03-2144 | All | All
Menus and some menu items rearranged for easier navigation. See updated user manual and/or updated online menu simulators for more details on revised menu order. Added ALL ON Keypad LED option. Allows easier identification of keypad buttons in vary dark operating environments. 1.3mag added as anamorphic desqueeze option. BM/CM DIT LUT now works with 4:4:4 RGB sources. BM/CM/DM PIP function renamed to PAP. PAP/PIP default mode now PAP. Added ability to toggle between PAP, PIP, POP, Vertical Split, and Horizontal Split by using up/down arrow keys while PAP function is active. DM DIT LUT name metadata now shown when LUT activated. DM250: Disembedded audio now in sync in Fast Mode This firmware update will require you to reload any DIT LUTs you are using. |
01.28.2016 | 1.1.02-2013 | All | Fixes DSLR Zoom bug. |
01.27.2016 | 1.1.02-2012 | All | Luminance mode behavior changed so that you no longer need to exit and reenter the System Menu to have access to the luminance level slider when in CUSTOM mode.
Resolves bug from previous release where function button would not illuminate when 3D DIT LUT function was activated. Resolves bug from previous release where DIT LUT would not activate until user pressed up/down key. LUT now activates when function is turned on. Resolves bug that prevented the Show PsF as P bug from working on the BM240. Resolves 720p24 compatibility bug from previous released. General improvements to locking speed and stability. |
01.07.2016 | 1.1.02-2009 | All | “Show PsF as” menu selection now only impacts interlaced and PsF signals. This improves usability by ensuring that no processing delay is added to progressive signals regardless of "Show PsF as" setting.
Resolved load default profile bug from previous firmware release that did not reset CIE Scope or 3D Disparity functions if active upon profile load. Removed ACES Proxy menu item from AM and LM series monitors as these units do not support ACES Proxy signals. |
01.04.2016 | 1.1.02-2008 | All | Adds symmetry grid marker.
New Luminance Mode selections: see user manual for details. BM, CM, DM Series Beta release of ACES Proxy (v1.0.0) monitoring modes for field testing. Contact Flanders Scientific for further details. Resolves Audio Loudness feature reset bug introduced in previous firmware. AM Series Resolves active Color Space indication bug. Color space indicated in temporary popup window when pressing input button will now match actual color space selected on Color Management Menu. DM Series Full raster measurement capability added to Video Data feature (same capability as BM and CM series). Automatic Payload ID detection improved for 3Gbps SDI signals. |
09.24.2015 | 1.1.01-2002 | DM250 | Improved 3Gbps SDI signal stability.
Improved Screen Capture integration with LiveGrade Pro. Several improvements to Fast Mode processing speed and quality. |
09.09.2015 | 1.1.01-2001 | DM250 | Improves 3g signal stability. |
08.17.2015 | 1.1.01-2000 | AM, BM, CM, LM | Adds new custom markers: TWC 2015 & Weather Channel 2015
Adds 17:9 marker Resolves intermittent 3Gbps SDI signal display bug Resolves no Audio mute with scope active bug |
08.07.2015 | 1.1.01-1999 | DM250 | Added support for DIT LUT position loading over USB, previously only calibration LUTs could be loaded via USB on the DM250.
Resolved Timecode display bug. Improved scope response speed. |
05.26.2015 | 1.1.01-1985 | ALL LCD Units | Resolves intermittent posterization artifact found in firmware version 1.1.01-1983. |
05.26.2015 | 1.1.01-1985 | BM, CM | Resolves Vertical and Horizontal split screen bug. |
05.20.2015 | 1.1.01-1983 | AM, BM, CM | Adds two new user created markers: History Channel and TWC 2015.
Adds new Color Space position titled R709-JM. Any user created calibration LUT may be placed here, but when selecting this color space position the CIE1931/Judd Color Matching selection becomes greyed out on the Color Management Menu. The only functional difference between placing this LUT in the USER1 position vs. R709-JM position is that in the R709-JM position the Color Matching Function menu item is not accessible in order to prevent accidental application of Judd Modified CMF on top of a user generated 3D LUT that already directly targets a Judd Modified CMF white balance. If creating a calibration 3D LUT to load into this position the file name should be titled jm.cfe Adds ability to override factory Rec709 position on OLED units so that operators can load there own calibration LUTs into these positions. This was previously locked out on OLED units with user access only being available on the user1, user2, and user3 positions. Improves signal locking speed when externally switching sources, especially for OLED units. Resolves H/V delay mode bug that showed grey instead of black background in blanking areas when H/V delay feature was activated. (BM & CM only) |
05.20.2015 | 1.1.01-1983 | LM & CM-170W | Adds two new user created markers: History Channel and TWC 2015. |
01.23.2015 | 1.1.00-1974 | CFE2 Units | Fixes Color Space name bug on popup ID window.
Adds custom LIFETIME marker. Beta support of scopes in new 2 input split screen modes. |
01.23.2015 | 1.1.00-1974 | LM Series | Adds custom LIFETIME marker. |
01.20.2015 | 1.1.00-1973 | CFE2 Units | Video Data Analyzer feature added.
CIE Scope feature added (see manual for feature limitations). 3D Disparity function added for 2 input monitoring. Signals must be same frame rate, resolution, and synced. New 2 inputs PIP modes added: horizontal and vertical split. Can be used with Variable Wipe feature for adjustable split positioning. BT.2020 Emulation added to color space selection menu. Camera Record Tally setting is now retained through power cycle. |
01.20.2015 | 1.1.00-1973 | LM Series | Camera Record Tally setting is now retained through power cycle. |
12.19.2014 | 1.0.00-1971 | CFE2 Units | CIE Measurement Feature: Select any point on screen to measure and plot its chromaticty values relative to your active color gamut selection. Additionally, you can select a secondary point on screen for comparative analysis of the two points. This comparison includes the ability to quantify the difference as a dE2000 value. Chromaticty can be plotted in either a CIE 1931 or CIE 1976 view. See page 13 of the updated user manual for details on this new feature.
Lock Brightness/Chroma/Contrast option added to the System Menu. Turn this ON to prevent accidental adjustment of current settings. The various upload and save CFE/LUT commands have all been consolidated into a single Update LUT command to simplify the LUT loading process. 1D DIT LUT support added. UP to 16 custom 1D DIT LUTs may be uploaded in addition to the 16 3D DIT LUTs already supported. File format uses .lut extension and valid LUT names are dit01.lut through dit16.lut. Support for this 1D LUT format will has already been confirmed for the next official LightSpace CMS release with more programs to follow. Improvements have been made to signal locking speed when switching sources. |
12.19.2014 | 1.0.00-1961 | LM & CM-170W | CIE Measurement Feature: Select any point on screen to measure and plot its chromaticty values relative to your active color gamut selection. Additionally, you can select a secondary point on screen for comparative analysis of the two points. This comparison includes the ability to quantify the difference as a dE2000 value. Chromaticty can be plotted in either a CIE 1931 or CIE 1976 view. See page 13 of the updated user manual for details on this new feature. |
11.18.2014 | 1.0.00-1965 | CFE2 Units | Corrected green screen display when selecting empty input. |
11.17.2014 | 1.0.00-1964 | CFE2 Units | PIP SDI ALT feature added. Unclean switch locking/freezing bug resolved.
Timecode selection via OSD no longer freezes out other function button selections. Canon camera SD signal support bug resolved. CIE Measurement featured added (BETA only). |
10.27.2014 | 1.0.00-1960 | CFE2 Units | 3D DIT LUT Feature Update: When the DIT LUT function is active you can now change between loaded 3D DIT LUTs by simply pressing the up and down arrow keys without having to enter the Color Management menu.
Brief on screen overlay now identifies active 3D DIT LUT. DVI-D Audio selection added: Channel 1 & 2. This capability only works on units shipped after October 27th, 2014. |
10.20.2014 | 1.0.00-1958 | CFE2 Units | Monitors now support storage of up to 16 3D DIT LUTs with revised .datV2 LUT format.
- LightSpace and Lattice both now export in this format. DIT LUT is now toggled on/off via assigned function button. - The 3D LUT that is toggled on/off is set on the Color Management menu by selecting the desired channel. 16 Channel Audio Loudness Monitoring has been added. Time Code can now be toggled on/off via Function Button. SDI Black Level Selection allows for easier full range vs. legal range monitor setup. Default gamma is now 2.4 and default luminance menu setting is 29. You may reset to previous defaults (2.2. and 35) by selecting those settings from the menu. Graticules Info On/Off toggle allows line position and span size information to be turned on/off when using the custom graticules marker feature. Fix for frozen screen when Show PsF as P was selected and H/V delay was toggled on. OLED models default Flicker Free On. |
6.18.2014 | 9.54-1951 | CM250 | Allows for scaling-free application of third party generated 3D calibration LUTs for more accurate
calibration of OLED units with third party software. Adds Graticules info on/off toggle. Allows for profiling with flicker free on or off (so no more need to switch to flicker free off). Adds “Outdoor” marker. **This is a Platform update that requires reloading the DCIP3.CFE file** |
5.21.2014 | 9.54-1950 | All | Adds settings to make graticules area solid or translucent in addition to single lines. Fixes intermittent bug when switching "show psF as" on CM250. |
5.15.2014 | 9.54-1949 | All | Adds Red Only, Green Only, Red Only as Mono, Green Only as Mono, Blue Only as Mono modes. Various user markers added. Fixes Horizontal Audio meter bug present while viewing interlace footage with show psF as P. Adds various user created markers. |
4.23.2014 | 9.53-1947 | CFE2 Units | Resolves white point shift bug when using P3 Color Space selection in combination with Flicker Free Mode On selection. Adds ability to reset Audio Loudness meter using RESET(VOLUME) rotary knob. |
3.20.2014 | 9.53-1945 | CFE2 Units | Adds audio monitoring support for 3G Level B signals including 12bit / 4:4:4 sources. Adds single channel audio loudness meter. Audio channel selectable from Audio menu. Resolves various 3G Level B viewing mode bugs (Stream selection, checkerboard display, vertical & horizontal split). |
3.13.2014 | 9.53-1944 | CFE2 Units | Updated Flicker Free Mode: resolves low level clipping on OLED units operating in Flicker Free Mode On |
2.28.2014 | 9.53-1941 | All Models | Adds S-Log3 Full and Standard |
2.20.2014 | 9.53-1938 | CFE2 Units* | Adds new markers: 2:1, TWC2014, Discovery V3. Updated color of OSD scrollbar. Fixed an issue with 3G Level B PIP. *CM320TD and CM500TD include updates from 9.53-1937, which was never released for those units. |
2.3.2014 | 9.53-1937 | CFE2 Units | New temporary on screen display window when input button is pressed detailing: Signal Resolution and Frame Rate, Active Color Space (Color Management Menu), Gamma Response (Video Menu), Color Matching Function (Color Management Menu). PIP function default now set to Picture and Picture (instead of windowed Picture in Picture), secondary input default now set to SDI 2 instead of CVBS. Adds BETA support for 4K signals over 2 x 3Gbps SDI inputs. Various other stability enhancements. |
12.27.2013 | 9.53-1934 | OLED | Adds flicker free mode On/Off toggle to Video Menu for OLED units. |
12.18.2013 | 9.53-1933 | ALL | Adds more custom marker selections. Adds Dual Link support for CFE2 Units. Adds 12bit 2K support for 3G. |
11.25.2013 | 9.53-1925 | ALL | Adds setting to display PSF as Progressive or Interlaced. Adds Max Sharpness function. |
11.21.2013 | 9.53-1923 | ALL | Fixes text overlap in menus. Adds Audio Loudness beta. Support for 12bit XYZ format. |
11.11.2013 | 9.53-1920 | ALL | Adds VU meter types: True Peak, PPM1, PPM2 Added Judd CMF for OLED Monitors Resolves Solarization Bug affecting small percentage of CM320TD low frame rate material |
10.21.2013 | 9.53-1907 | ALL | Adds updated audio meters with adjustable peak hold. Adds new Udisk mode for easier firmware and LUT update. Adds custom markers: NatGEO and TWC Safety 2013 |
9.05.2013 | 9.53-1901 | ALL | Adds Hue Vector Scope Improves Interlaced Video Processing Adds new PIP function with corresponding selections in System menu for BM / CM Series. |
8.31.2013 | 9.52-1897 | BM / CM Series | Resolves interlaced video processing bug. Adds support for DIT LUT |
8.06.2013 | 9.52-1894 | BM / CM Series | Adds Hue Vector Scope *Released with MHD version 1.4 for CM320TD Resolves issue that may have distorted display of some illegal video levels Various 3gbps SDI format support improvements |
8.13.2013 | 9.51-1890 | LM Series | Adds Hue Vector Scope |
7.05.2013 | 9.51-1884 | BM210, BM230, CM171, CM240 | Resolves issue where first line of some interlaced sources was not shown correctly. Resolves 4:4:4 YCbCr Level B 3Gbps signal support bug. |
7.03.2013 | 9.51-1883 | BM210, BM230, CM171, CM240 | Fixed issue where Timecode fails to display. Fixed bug where 1st line of some interlaced sources did not display correctly. |
6.26.2013 | 9.51-1880 | BM210, BM230, CM171, CM240 | Improves de-interlacing performance in all video processing modes |
6.24.2013 | 9.51-1878 | BM210, BM230, CM171, CM240 | Improves de-interlacing performance in all video processing modes |
5.7.2013 | 9.51-1870 | ALL | -Adds SLog2 monitoring mode to all units. *NOTE: For units with CFE Boards (CM-170, LM-2461W, LM-2460W, etc.) you MUST first update to 9.50-1866 before updating to 9.51. If you skipped the 9.49-1863 CFE update you will also need to load the full CFE package now available with 9.50-1866 before updating to this firmware version. If you have any questions about this please contact support@flandersscientific.com or +1.678.835.4934 |
3.26.2013 | 9.50-1866 | ALL | -Adds BMD-Log Standard & BMD-Log Full monitoring modes to all units. These Log modes are designed for monitoring of the Black Magic Design Cinema Camera Film Mode output in on set / live monitoring applications. Like the C-Log and S-Log modes already on the monitor the Standard Mode works well on the majority of footage whereas the Full Mode is best used on very bright scenes. See the user manual for more details. -This firmware version in conjunction with an updated 'code.bin' file resolves a firmware version 9.49 bug impacting LM-2460W, LM-2461W, and CM-170 where some illegal levels (over 106IRE) may have been shown as yellow on screen. Firmware 9.50 + the revised model specific code.bin resolve this potential bug. -Adds revised DISCOVERY marker. *This is a required platform firmware update before subsequent firmware updates are preformed. All users will need to update to this firmware before updating to subsequent firmware versions. |
2.21.2013 | 9.49-1863 | ALL | -Recording Status Tally feature now works with SDI signals coming from Canon cameras like the C300. -New Timecode Background option. Allows you to select between solid blue and translucent black background options. This works in both the newer large timecode and traditional smaller timecode view modes. -Audio Phase Indicator has been added as an optional display item in Safety Broadcast Mode. You can activate this via the Alarm Menu. -Several new custom user created markers are now available including 3.125:1, 6.25:1, and Adobe. In addition to the updates above the following updates will apply to the LM-2461W, LM-2460W, and CM-170: -Custom calibration 3D LUT import capabilities have been added. This includes the addition of 3 USER color space positions so that custom calibration LUTs can be loaded without needing to override standard color space selections. Specifically, customers using the latest version of Light Illusion’s LightSpace CMS can already export LUTs in FSI’s 64x64x64 3D LUT format for import to the monitor. See the user manual for more details. -Updated CFE Package has been issued in conjunction with this firmware. This includes an updated code.bin file as well as new Rec709, EBU, and SMPTE C color space files. These new files further refine color accuracy, especially in lowlight tracking, and are based on the latest data collected from new reference instruments. You must load these updated files after updating to 9.49-1863 or later firmware. *old code.bin, Rec709, EBU, SMPTE C files have been replaced by updated files. The old Rec709.dat has been renamed and reolcated to user1.dat. |
11.19.2012 | 9.47-1941 | ALL | -Adds Timecode Background Option (choose between solid blue and translucent black) -Adds Audio Phase Alarm to Alarm Menu |
10.18.2012 | 9.47-1837 | ALL | -Adds Timecode Size option to OSD menu. Select between standard small mode and the new large mode. *Note: XYZ support continues in beta form in this release. -Adds On-Screen tally option. Activated via function menu and generates an onscreen tally window that mirrors the status of the physical tally. |
9.27.2012 | 9.47-1830 | ALL | -Adds fast access to Log monitoring modes via Function button assignment. -Adds Rec. Status Tally indicating via monitor tally light when camera is recording. Designed for use with cameras that output Start/Stop Record Flags in the ancillary data of their serial digital output. Currently supports Sony and ARRI Alexa cameras with SDI start/stop record flag feature enabled. See user manual pg 16 for more details. -Adds 12bit processing and signal support to all monitors with 3Gbps SDI inputs. Payload ID detection is enabled for all RGB and YCbCr signals, whether 10bit or 12bit, but manual selections of 4:4:4 RGB 12bit, 4:4:4 YCbCr 12bit, and 4:2:2 YCbCr 12bit have been added to the SDI Format menu toggle for signals without Payload ID present. -BETA support of XYZ signals has been added to all monitors with 3Gbps SDI inputs. When sending an XYZ signal to the monitor you must manually select 4:4:4 XYZ 12bit from the SDI format setting on the Video Menu. The XYZ signal will be mapped to the color space set on the Display Alignment menu. Some XYZ signals may not be fully supported at this time. Please contact Support@FlandersScientific.com or +1.678.835.4934 for assistance or feedback. |
8.14.2012 | 9.46-1812 | ALL | -Adds Log Mode selection to Video menu. Select from OFF (default), C-Log Standard, C-Log Full, S-Log Standard, or S-Log Full. Allows for easier On Set monitoring of uncorrected C-Log or S-Log signals. See the updated PDF user manual for more details. -Removes Film Gamma menu item and replaces it with Gamma Select menu item. This change also removes the UNCORRECTED setting that would simply disable a monitor's calibration. |
6.25.2012 | 9.46-1806 | ALL | -Adds Audio Lockout Feature. When Audio Lockout is set to ON from Audio menu the Volume knob will retain the last used setting and cannot be adjusted or muted until Audio Lockout is set back to off. |
6.5.2012 | 9.46-1805 | ALL | -2048x1080p25 and 2048x1080psf25 signal support added -Marker color bug resolved. Marker color selection will now be remembered for each individual marker profile -New user created Custom Markers added to Area Marker options |
4.26.2012 | 9.46-1798 | ALL | -New OSC viewing mode added for LM-0750W only. Allows any two scopes to be viewed along with an Audio Phase Meter and 2 Channel Audio Level Meter in a quad view with the live video signal. Set OSC mode to On from the Scopes and VU Meters menu to activate this mode. -Added diagnostic viewing modes for 3D signals over 3Gbps Level B SDI including Checkerboard and Disparity Check to all monitor models. The checkerboard mode allows for adjustable checkerboard size via the Checkerboard size option on the System Menu. |
2.27.2012 | 9.45-1779 | ALL | -Updated TWC SAFETY Marker, replaces old TWC marker -Added 16by9 in 4by3 marker for HD Signals. Shows a box outlining the 16by9 portion of a 4by3 cutout of an HD video signal. |
1.17.2012 | 9.45-1777 | ALL | -RGB and GBR Parade Scopes now feature color coded Red, Green, and Blue Channels. -Still Frame improved to allow for color critical use -Focus Assist feature updated so that feature works over entire image, not just windowed portion of signal. |
1.8.2012 | 9.44-1770 | ALL | -Adds ability to adjust volume while Scopes are active, you no longer need to disable onscreen scopes before adjusting volume. -Improves Audio Phase Metering Accuracy |
12.1.11 | 9.44-1760 | ALL | -Adds ability to use markers while CX Scale is active -Some factory default settings changed (activated by loading 'default' profile) to more commonly used function button and scopes and VU meters configurations. -RGB Scope Mode renamed to RGB Parade. GBR Scope Mode renamed to GBR Parade. |
11.1.11 | 9.43-1754 | ALL | -Adds CX Scale Feature on Function Menu. Allows for 1 button access to a custom scaling mode allowing for full screen and centered scaling of serial digital output from Codex ARRIRAW Onboard Recorders -Resolves Intermittent image distortion bug when entering/exiting AFD and/or Anamorphic De-Squeeze functions. |
9.26.2011 | 9.42 | ALL | -New Custom Markers:Discovery & WS-SAFE-A-T -New unlockable SDI HUE adjustment option. Found on System Menu, select SDI HUE Adjustment On or Off. When On Hue adjustment knob will become active even on SDI signals. Please note that the default position is correct so HUE should not be adjusted unless you have a specific applicaiton requirng such an adjustment. -Default Scope Intensity level has been changed from 50% of maximum to 75% of maxium intensity. You can still adjust the intensity level using the the H POS rotary knob while your socpe is on screen. -Anamorphic Desqueeze feature added. When activated via a funciton button the monitor will automatically adjust the aspect and/or magnifaciton of your incoming signal by the ratio selected for Anamorphic Desqueeze on the Video menu. Select from 1.3, 2.0, or 2.0mag. -RGB and GBR parades indications have been shifted right to avoid overlap with the IRE level scale on the left of the scope window. -SD Enhancement Selection added to Video Menu, activates max sharpening and image enhancement for SD video signals. -Mono Mode and SD Aspect Ratio removed from Video Menu, still accessible via function button assignment. -AFD Function added providing AFD code and detail readout as well as onscreen marker indications of AFD described areas. -Pixel Position function removed. When activating Pixel Mapping the H POS rotary knob now automatically becomes the Pixel Position Toggle (press down on knob to toggle) therefore freeing up another funciton butotn position for those wishing to use pixel positon in conjunction with pixel mapping. |
5.23.2011 | 9.41 | ALL | -Adds Overlay Mode to 3Gbps Level B viewing mode options. Overlay mode allows for proper viewing of a combined LinkA and LinkB stream (372M format mapping) over the Level B 3Gbps SDI Inputs -Resolves various Level A 3Gbp SDI bugs -Adds TWC-HD1 Custom Marker -Still Frame feature updated to work on high resolution progressive signals -Safety Broadcast featue added to funciton menu. UMD Display, Color, and Position as well as audio meter toggles added to Alarm Menu for Safety Broadcast adjustment -IRE Trigger Level scale changed from Digital Levels to IRE scale |
4.28.2011 | 9.40 | ALL | -Adds 3Gbps SDI Level B monitoring options to units equipped with 3Gbps SDI Inputs. Select between monitoring Stream 1, Stream 2, PAP (picture and picture), PIP (picture in Picture), POP (picture on picture, inverse of PIP), Vertical Split, and Horizontal Split. Selection is found on System Menu and labeled 3G Level B. -Bug causing image loss when Overscan was activated while viewing component analog sources has been fixed. -LevelB Variable Wipe Function added. Only for use with Level B 3Gbps SDI signals on 3Gbps SDI equipped monitors, allows adjustment of Split Screen positioning in Horizontal/Vertical Split monitoring modes. -Sub Window bug preventing scopes from working while Sub Window is active has been resolved. -Removes MUTE indication from Audio Level Meters, replaced by NO DATA indication if embedded audio is not present. -Intermittent Vector Scope Gain expansion bug preventing 2x Gain expansion from being selectable has been resolved. -Adds Alarm Menu to monitor with ability to select onscreen alarm triggers. Onscreen Alarms do not require older units to be updated by FSI, this firmware update will enable this ability. Update at FSI's service facility will only be required for remote alarm monitoring via external software. See Manual for Details on Alarm Monitoring capabilities. -Add Source ID window to list of available Scope Windows. Source ID window is capable of showing manual Source ID, Remotely programmed UMD, and Tally Light status. -Adds DSLR Zoom function allowing for full screen scaling of 1080 and 480 DSLR outputs. See User Manual for details on DSLR Zoom feature. -Additional Permitted Max Level Added to Audio Level Meters: -10dBFS -Still Frame feature added. Allows user to freeze any frame of video with a function button, please note that this is limited to a max resolution of 1920x1080 and cannot be used in conjunction with other functions. -LUM Coloring feature updated. Middle range now adjustable in addition to max/min range. Middle Range will show as greyscale by default, but can be adjusted by using rotary knobs. See User Manual for details. -Graticules (Custom Marker) function has been updated to include a Span Width readout showing size (in pixels) of the box created by the graticules feature. -Ability to view just channels 1 & 2 added to audio level meters to allow for minimal overlap of active video in Horizontal Audio Level Meters mode compared to monitoring 8 or 16 channels of audio. |
2.2.2011 | 9.38 | ALL | -Adds 3 New Scopes: YCbCr Overlay, RGB Overlay, and Audio Phase Meter -Previous Flesh Tone Line on Vector Scope has been replaced by i-line axis. -Adds 3 Marker Profiles allowing for instant switching between three user configured Marker Layouts using designated Function Buttons -Updates Audio Level Meters with more detailed Scales -Updates Audio Level Meters with new feature that will show a MUTE indication in any Audio Channel that has no audible volume, but is part of an embedded Group of Audio. If nothing is shown (No audio level and not MUTE indication) then the Group of Audio associated with that channel is not embedded into the SDI signal. -EBU/SMPTE Audio Selection replaced by Alignment Level Selection -Adjustable Permitted Max Level Added to Audio Level Meter Settings |
11.18.2010 | 9.37 | ALL | -Adds Scopes & VU Meters Profiles, Blue Only, Crosshatch, H/V Delay, Overscan, and LUM Coloring to GPI menu options -Resolves bug preventing scopes from being used on some monitors while Sub Window mode is active. -Updates Sub Window Mode. Image now frozen/unfrozen using H POS rotary knob. Ability to switch to second input of same resolution after image is frozen on first input. -Resolves 8bit Measurement Feature bug showing bogus value if Luminance Value in Diff row was negative. |
9.30.2010 | 9.36 | ALL | -Adds Stackable Scopes Toggle. From the Scopes & VU Meters Menu use the Scopes Stack option to select whether your two scope windows are placed horizontally next to each other or are vertically stacked on top of one another -8bit measurment mode modified so that absolute RGB values show 1:1 correspondence with incoming signal. Measurment Mode will now allow for percentage values above 100%. -Vector Scope Gain Adjustment added. Select between 1x, 2x, or 4x Gain by turning the V POS Rotary knob while Vector Scope is turned on. -Focus Assist Window may now be moved to different parts of the screen faster. -More detail added to Vector Scope with addition of IRE lines and skin tone line -YCbCr and RGB Histogram Scope Modes added -RGB order added as option for parade waveform. You may now select whether to view parade waveform in RGB or GBR configuration. -Pixel Zoom Feature added. When turned on you can use the H POS and V POS rotary knobs to select any area on screen to zoom into. You can use the REF POS rotary knob to change the size of the Pixel Zoom rectangle. Pressing down on the Ref POS rotary knob while Pixel Zoom is on activates the zoomed mode. See user manual version 2.3 or later for more details on this feature. -10bit Measurement Mode added in addition to 8bit Measurement Mode. Measurement mode now allows you to move in 1 pixel increments. Measurment mode will also allow you to change the sample size from a block of hundreds of pixels to just a single pixel by turning the REF POS rotary knob. See user manual 2.3 or later for more details on this feature. -Timecode Position option. You can now move the timecode window to any of 6 onscreen locations. |
7.28.2010 | 9.35 | ALL | -Adds SD Aspect Toggle to Function Menu -Updates to Marker Graticules Function to indicate proper postioning notification on screen. -Addition of Full Screen Function. Allows you to stretch any source to fill the screen. Unlike the Zoom Function the Full Screen Function does not preserve the native aspect ratio of the source, but does keep all of the active video visible. This function is most useful when used with some rasterizters that allow for a widescreen 1024x768 DVI signal. The Full Screen function allows such sources to be seen on screen as intended. -Adds Histogram and Color Histogram features to the Scopes Function. -Audio Sync Setting added to Audio Menu. Allows you to select between signal clock or internal clock. This toggle can improve audio disembedding quality depending on the source in use. If you experience any audio disembedding distorition try changing this setting to improve quality. -Lum Coloring Feature's scale will now follow the Waveform Scale set in the the Scopes and VU Meters Profile 1. Lum Coloring Feature has also been updated to represent overexposed areas in white and underexposed areas in black. |
5.20.2010 | 9.30 | ALL | -Adds ability to view any two Scopes Modes onscreen at the same time. Please note that if two Scopes Modes are displayed at the same time they will update more slowly than if using just one Scopes Mode at a time. -Adds Focus Assist feature. Reference 'in focus' level is adjustable with rotary knob. -Adds GPI Keylock feature allowing keypad (all buttons except for power button) to be locked out via GPI remote control. -Adds Custom Graticules feature allowing user to set 4 lines anywhere on screen to create a custom marker. Line positioning is controlled with rotary knobs when function is activated. -Adds Line/Sample difference values to Measurement function. -Adds ability to view any two Scopes Modes onscreen at the same time. Please note that if two Scopes Modes are displayed at the same time they will update more slowly than if using just one Scopes Mode at a time. -Adds Focus Assist feature. Reference 'in focus' level is adjustable with rotary knob. -Adds GPI Keylock feature allowing keypad (all buttons except for power button) to be locked out via GPI remote control. -Adds Custom Graticules feature allowing user to set 4 lines anywhere on screen to create a custom marker. Line positioning is controlled with rotary knobs when function is activated. -Adds Line/Sample difference values to Measurement function. -Adds ability to view any two Scopes Modes onscreen at the same time. Please note that if two Scopes Modes are displayed at the same time they will update more slowly than if using just one Scopes Mode at a time. -Adds Focus Assist feature. Reference 'in focus' level is adjustable with rotary knob. -Adds GPI Keylock feature allowing keypad (all buttons except for power button) to be locked out via GPI remote control. -Adds Custom Graticules feature allowing user to set 4 lines anywhere on screen to create a custom marker. Line positioning is controlled with rotary knobs when function is activated. -Adds Line/Sample difference values to Measurement function. -Adds ability to view any two Scopes Modes onscreen at the same time. Please note that if two Scopes Modes are displayed at the same time they will update more slowly than if using just one Scopes Mode at a time. -Adds Focus Assist feature. Reference 'in focus' level is adjustable with rotary knob. -Adds GPI Keylock feature allowing keypad (all buttons except for power button) to be locked out via GPI remote control. -Adds Custom Graticules feature allowing user to set 4 lines anywhere on screen to create a custom marker. Line positioning is controlled with rotary knobs when function is activated. -Adds Line/Sample difference values to Measurement function. -Adds ability to view any two Scopes Modes onscreen at the same time. Please note that if two Scopes Modes are displayed at the same time they will update more slowly than if using just one Scopes Mode at a time. -Adds Focus Assist feature. Reference 'in focus' level is adjustable with rotary knob. -Adds GPI Keylock feature allowing keypad (all buttons except for power button) to be locked out via GPI remote control. -Adds Custom Graticules feature allowing user to set 4 lines anywhere on screen to create a custom marker. Line positioning is controlled with rotary knobs when function is activated. -Adds Line/Sample difference values to Measurement function. -Adds ability to view any two Scopes Modes onscreen at the same time. Please note that if two Scopes Modes are displayed at the same time they will update more slowly than if using just one Scopes Mode at a time. -Adds Focus Assist feature. Reference 'in focus' level is adjustable with rotary knob. -Adds GPI Keylock feature allowing keypad (all buttons except for power button) to be locked out via GPI remote control. -Adds Custom Graticules feature allowing user to set 4 lines anywhere on screen to create a custom marker. Line positioning is controlled with rotary knobs when function is activated. -Adds Line/Sample difference values to Measurement function. Resolves vBit Bug issue causing some NTSC sources to be positioned to low on screen (leading to bottom portion of video not being shown) depending on vBit line position. This release will resolve this problem and keep active video centered on screen regardless of vBit positioning. Adds password protection step to reset factory alignment function. |
3.18.2010 | 9.26 | ALL | -Replaces current 4 level sharpness setting with sharpness level slider offering 30 different levels to choose from. -Improves Accuracy of Waveform indications and onscreen display of levels with component video signals |
1.10.2010 | 9.23 | ALL | -LUM Coloring feature added. See user manual for details. -Resolves firmware version 9.21 LM-2450W flickering marker bug |
12.7.2009 | 9.21 | ALL | -Optimized LUTs added for LM-2450W allowing for more accurate replication of available color space selections. These optimized LUTs also include the gamma accuracy optimization, first added in version 8.14, that were accidentially left out of version 9.20 firmware. -Audio Disembedding bug from 9.20 that may have caused distortion in audio channels 3 through 16 with some formats is resolved in 9.21 -Please note that starting in version 9.21 two versions of firmware will exist for the LM-2450W models. To select the correct version to upload check your version in the System Status Menu and match to the appropriate firmware version. |
10.29.2009 | 9.20 | ALL | -RGB Gain and Offset Adjustments added to display alignment menu. If you would like to tweak the RGB settings please do so by using these settings. You do not need to press the Reset Factory Alignment Menu to operate the RGB Gain and Offset functions and we DO NOT recommend that you Reset to Factory Alignment unless specifically asked to do so by an FSI support representative. Similarly, please do not operate the Start Display Alignment Function unless you are in possession of an FSI automatic alignment kit. -Reset Factory Alignment bug resolved. In firmware version 9.16 selecting the Reset Factory Alignment option from the Display Alignment Menu could cause the monitor's screen to become inoperable until updated. This update resolves this bug and can be used to renable the monitor if this bug was encounterd by user in 9.16. |
9.30.2009 | 9.16 | ALL | -Three Scopes & VU Meters Profiles added. Each Scopes & VU Meters profile can be assigned to an individual Function button for instantaneous switching between Waveform, Vector Sope, and VU Meter modes -Video Clipping function modified so that the correct default Chroma value regardless of Video Clipping status is 0. If you have Video Clipping Off and Chroma value currently set to -17, please reset your Chroma value to 0. -Measurment function added. Once assigned to a function button can be used to measure YRGB levels of any spot on screen by using H Pos and V Pos rotary knobs to highlight area to be measured. Pressing the F.D. (Find Delta) rotary knob allows you to establish a reference position and compare to any other onscreen positon. Pressing the contrast knob while Measurment function is active allows you to establish an F-Stop reference value and compare differences between onscreen positions as an F-Stop Value. Pressing the Volume knob while Measurment function is enabled resets/clears this F-Stop information from the screen. -Drop Frame Timecode bug resolved. Earlier firmware versions may not have shown frame counts correctly when drop frame timecode was being used. This issue is resolved in 9.16. -Measurment function crosshairs will follow color of markers -Safety in Area function added to Marker menu. With this function set to ON your safety area will be shown realitive to your desired area marker (ie 4:3). With this function set to OFF your Safety Area will be shown relative to the incoming source. -Lum Coloring Feature added to Menu, but not yet active. This feature will be added in future releases. -After installing this update all future updates may be installed with either the traditional upload program (32 Bit Windows Systems Only) or via a new mass storage firmware update path. You must install 9.16 or later firmware with the traditional update program BEFORE this mass storage firmware update method will work. Once installed future updates may be loaded with any computer supporting USB mass storage devices. To activate USB mass storage update mode the following key sequence should be pressed while the monitor is plugged in, but the power is left off (Red power LED not lit): MENU, ENTER, UP, DOWN, MENU, ENTER, UP, DOWN, MENU, DOWN, POWER. Then simply drag and drop the new firmware to the root directory of the monitor (monitor will show up as USB mass storage device on computer). Once the firmware has been successfully copied to the monitor (mass storage device) the Update Firmware menu item on the Display Alignment Menu will become active (no longer greyed out), simply select this feature to complete the update of your monitor. -Toggle Backlight function added to GPI menu. This is a power saving function that toggles between your default backlight setting and the minimum (but still on) backlight setting. |
8.5.2009 | 9.13 | ALL | -Component Setup Feature Added (Select from YPbPr SMPTE/N10, YPbPr Betacam, and YPbPr MII) -Vbit bug resolved that may have caused sync loss on some SD-SDI sources with Vbit on line 10 when using 9.06-9.11 firmware -2.4:1 Marker Added -Video Clipping default setting changed to OFF -Alignment Safety step added with 'are you sure' step after 'start display alignment' selection -Color Temp, Marker Color, etc. now actively reset when loading default or user profiles -'NTSC Setup' renamed 'Composite Setup' & composite setup bug causing clipping of sub black levels in analog composite resolved. |
8.5.2009 | 9.12 | Only Ships on New Units | -Component Setup Feature Added (Select from YPbPr SMPTE/N10, YPbPr Betacam, and YPbPr MII) -Vbit bug resolved that may have caused sync loss on some SD-SDI sources with Vbit on line 10 when using 9.06-9.11 firmware -2.4:1 Marker Added -Video Clipping default setting changed to OFF -Alignment Safety step added with 'are you sure' step after 'start display alignment' selection -Color Temp, Marker Color, etc. now actively reset when loading default or user profiles -'NTSC Setup' renamed 'Composite Setup' & composite setup bug causing clipping of sub black levels in analog composite resolved. |
7.17.2009 | 9.11 | DO NOT REPLACE 9.10 WITH 9.11 | -Adds System Menu Notification of unit as 3G if 3G board is installed -Changes default NTSC setup to 7.5, not 0 as in firmware 0.9.08/0.9.09 -3 User Profiles added for Waveform / Vector Scope Function, which allow all Scopes and VU Meters preferences to be saved into 1 of 3 selectable profiles -Resolves NTSC setup bug that caused user selected NTSC setup option to be lost when switching to/from composite input -Solves potential compatibility issue with SD-SDI output from some Digibeta decks |
7.17.2009 | 9.10 | Only Ships on New Units | -Adds System Menu Notification of unit as 3G if 3G board is installed -Changes default NTSC setup to 7.5, not 0 as in firmware 0.9.08/0.9.09 -3 User Profiles added for Waveform / Vector Scope Function, which allow all Scopes and VU Meters preferences to be saved into 1 of 3 selectable profiles -Resolves NTSC setup bug that caused user selected NTSC setup option to be lost when switching to/from composite input -Solves potential compatibility issue with SD-SDI output from some Digibeta decks |
1.9.2009 | 9.09 | 9.06 | DO NOT REPLACE 9.08 WITH 9.09 - Adds clipping function in "Display Alignment" menu -Adds 1080p 25/30Hz support for DVI-D input -Adds 1920x1200 60hz support for LM2450W (may require EDID update to monitor for certain graphics cards) -Adds NTSC setup setting in "Video" menu -Adds SDI Format selection in "Video" menu |
7.9.2009 | 9.08 | Only Ships on New Units | - Adds clipping function in "Display Alignment" menu -Adds 1080p 25/30Hz support for DVI-D input -Adds EBU 2.35 gamma -Adds 1920x1200 60hz support for LM2450W -Adds NTSC setup setting in "Video" menu -Adds SDI Format selection in "Video" menu -Adds 5000K Color Temperature Selection |
6.29.2009 | 9.06 | ALL | -Adds Timecode Feature (LTC, VITC 1, VITC 2) -Analog YPbPr vs RGB Toggle added -DVI Format Selection (YPbPr, Full RGB, Limited RGB) -Waveform Position feature added -H/V Delay Feature added -Push Button Audio Mute added -3G Status ID labeling if Signal is 3G added -AutoSync between 4:4:4 RGB and 4:4:4 YPbPr added -Adds support for 720p24/25/30 -NTSC Setup (0 or 7.5 IRE) added -Active Boundary Marker feature added |
6.12.2009 | 0.8.22 | 8.16 | Improves Synchronization with 1080 sources and provides more accurate distinction between possible 1080 framerates. Resolves Potential Sync Loss Issue. |
5.7.2009 | 0.8.16 | All | Disembedded audio now in sync for all signals / processing modes Same Gamma fix as 0.8.14 |
5.1.2009 | 0.8.14 | None | Gamma Accuracy improved |
4.28.2009 | 0.8.13 | ALL | HW w/o Audio Fix Only - H/V Delay added in menu but not operational yet Audio disembedding on SD fixed |
4.28.2009 | 0.8.12 | ALL | HW w Audio Fix Only - H/V Delay added in menu but not operational yet Audio disembedding on SD fixed |
4.28.2009 | 0.8.11 | ALL | HW w/o Audio Fix Only - DVI-D Pixel Format Selection (Full RGB, Limited RGB and YCbCR) - Reduced switching delay - Support for DVI 1280x768@60, 1366x768@60, 1440x900@60- DVI-D Pixel Format Selection (Full RGB, Limited RGB and YCbCR) - Reduced switching delay - Support for DVI 1280x768@60, 1366x768@60, 1440x900@60 - Fix for Audio disembedding on fractional HD formats |
4.28.2009 | 8.10 | ALL | HW w Audio Fix Only - DVI-D Pixel Format Selection (Full RGB, Limited RGB and YCbCR) - Reduced switching delay - Support for DVI 1280x768@60, 1366x768@60, 1440x900@60- DVI-D Pixel Format Selection (Full RGB, Limited RGB and YCbCR) - Reduced switching delay - Support for DVI 1280x768@60, 1366x768@60, 1440x900@60 - Fix for Audio disembedding on fractional HD formats |
4.19.2009 | 8.07 | None | FSI Default settings Audio disembedding on 25 and 50 signals impoved, but all others not. |
4.19.2009 | 8.06 | None | FSI Default settings Audio disembedding on 25 and 50 signals improved |
4.18.2009 | 8.05 | ALL | HW w Audio Fix Only |
4.10.2009 | 8.04 | 0.7.07 (LM-2450 only) | 0.8.03 fixes + 3DLUT for Rec 709 and EBU Sparkles in Video Field Reversal 24psf Noise Reduction0.8.03 fixes + 3DLUT for Rec 709 and EBU Sparkles in Video Field Reversal 24psf Noise Reduction |
4.10.2009 | 8.03 | 0.7.07 and 0.7.08 (ALL except LM-2450) | Blue Only Remains when changing Brithness setting etc LED's OFF turns off both Power and Input LEDBlue Only Remains when changing Brithness setting etc LED's OFF turns off both Power and Input LED |
4.7.2009 | 8.01 | 24" only | FSI Internal Use Only |
4.6.2009 | 8.00 | none | FSI Internal Use Only (Audio Test) |
4.1.2009 | 7.09 | 24" only | FSI Internal Use Only (3D LUT test) |
3.24.2009 | 7.08 | 17" only | - Gamma correction 17" |
3.23.2009 | 7.07 | 0.7.06 | - Attempted Fix for Audio Issue partly solved (crackling noise eliminated but stil distortion of the embedded audio (clicking noise) -Partial Color Temp Improvement |
3.22.2009 | 7.06 | 0.7.04 | Marker 15:9 - New Menu sructure; Function - Scopes & VU-Meters - Video - Audio - Marker - System - OSD - GPI - Display Alignment - System Status - Support - Staus overview (Zoom, Blue, Marker, Overscan, Subwindow, Pixel Mapping, Pixel Position, Mono Mode, Scopes & VU-Meters, Crosshatch, Processing - Alignment procedure offers option to skip the 30min waiting time, total alignment time now 20minutes - Sharpness level setting "Medium" renamed to "Default"- Alignment procedure offers option to skip the 30min waiting time, total alignment time now 20minutes - Sharpness level setting "Medium" renamed to "Default" |
3.17.2009 | 7.04 | 0.7.00 | - Audio Level Meters: Selection Channels 1-8, 9-16 or 1-16 - WFM Digital Level Values 0 and 255 - WFM Digital Level now also available for RGB and Column WFM displays- Audio Level Meters: Selection Channels 1-8, 9-16 or 1-16 - WFM Digital Level Values 0 and 255 - WFM Digital Level now also available for RGB and Column WFM displays - LM-2450W Strobing effect on 1080i23.98psF - Crosshatch in Pixel to Pixel Mode - Markers in Pixel to Pixel Mode (but in center pos only) - "Overscan" instead of "Over Scan" In OSD text - Live update of function status in OSD/System Status Page- LM-2450W Strobing effect on 1080i23.98psF - Crosshatch in Pixel to Pixel Mode - Markers in Pixel to Pixel Mode (but in center pos only) - "Overscan" instead of "Over Scan" In OSD text - Live update of function status in OSD/System Status Page |
3.18.2009 | 7.02 | none | FSI Internal Use Only |